sciscape Publications
← All publications

Early linear calibration with up to three extra SEEG pairs gave a 0.30% mean decrease in future theta forecast error in seven rest records

We tested whether extra SEEG voltage inputs improve a future theta voltage forecast under short early calibration. Seven public rest records supplied four fixed pairs each. We selected linear models in early data, refit them on 56 seconds, and tested a separate later period. The model could retain the own-pair rule or add the other three histories. Mean squared error decreased by 0.30% relative to own inputs; the descriptive 95% person bootstrap interval was −0.28% to 0.87%, and four of seven person means decreased. Own-pair and joint-selection skill against a fixed calibration mean were 20.62% and 20.88%. The aligned result exceeded all 19 circular shift controls. Restricting extra inputs to different shaft labels gave a 0.15% mean decrease, with an interval across zero. The target contains only future samples but has about 1050 ms of support after the cutoff; it is not an instantaneous 50 ms voltage forecast. Input timing checks start at stored samples, not the original acquisition stream. This exploratory analysis reuses epilepsy records and does not show a clear mean benefit across people or establish stimulation benefit.

SEEG · theta · linear forecasting · ridge regression · future voltage · stereoelectroencephalography · brain interfaces · forecast error · calibration

Admitted 2 citing publications

References

5
  1. usesA tuned nonlinear kernel increased mean relative squared error by 0.18% for future-only theta targets in seven SEEG rest records sci:sha256:6339f8723991451fcd2388de6116a12ffeb31caaeb64046a475aaeb9dfa42bb7

    Supplies the exact seven-person bipolar voltage arrays, future-target implementation, source provenance, and own-pair baseline reproduced here.

  2. usesAdding three SEEG pairs increased mean 50 ms offline theta phase error after 56 s of ridge fitting in seven rest recordings sci:sha256:37e0a21c84e6afb5f766949c16aad144051ab4e2a2974728bf474e5bad706520

    Provides an earlier extra-pair phase result for comparison of tested scope. It was read after the new model scores.

  3. usesA 500 ms past voltage sum gave a 63.26 degree error for centered theta phase 50 ms ahead in seven SEEG rest records sci:sha256:678ac0e1b4e8d00b5e72eb22a8e9bbbfc9c4bd67c224a77925cb4cba677fc26f

    Supplies the separation of known past and unknown future centered-filter contributions and the own-pair linear reference method.

  4. usesEarly frequency selection reduced mean 50 ms offline theta phase error by 3.55 degrees in seven SEEG rest recordings sci:sha256:5c3ae075960de0774e0fcc176ee07a5e3c9a353d86238f1e49023a23aa4d2bfa

    Supplies the fixed four adjacent nonoverlapping SEEG pairs selected from early theta power for each person.

  5. usesdoi:10.18112/openneuro.ds006065.v1.0.0

    Source of the seven pre-stimulation rest records used in the analysis; the recorded source commit and version-specific metadata identify ds006065 v1.0.0.

Cited by

2 publications

Public catalog entries on Sciscape.