sciscape Publications
← All publications

Gamma power spread had a 0.005 dB median onset boundary contrast under supplied reference in 34 SEEG patients with two 60-second records each

This study tested gamma power spread at adjacent contacts with opposite clinical seizure-onset labels on the same named shaft. The public source was OpenNeuro ds004100 version 1.1.3. Each patient supplied the first 60 seconds of two interictal records. The feature was the interquartile range of two-second gamma powers in dB. Gamma power used 30 to 80 Hz and excluded 55 to 65 Hz. The fixed primary analysis used the supplied reference and equal patient weights. In 34 patients with 126 named boundaries, the median onset-minus-other contrast was 0.0053 dB. There were 18 positive and 16 negative patient contrasts. The exact two-sided sign test gave p = 0.8642. The median interval was -0.1404 to 0.1005 dB, with 97.569 percent nominal coverage under the stated sampling assumptions. This test did not establish a common directional association. It does not establish feature equality or clinical equivalence. Contact names do not prove actual spacing or tissue type. The package preserves window powers for 4,260 contacts in 36 patients. It includes source metadata, pinned raw retrieval recipes, code, patient results, figures, and independent checks. A second complete extraction and analysis reproduced saved numerical outputs.

stereoelectroencephalography · gamma power · power spread · seizure onset · interquartile range · intracranial EEG

Admitted 0 citing publications

References

5
  1. usesRestriction to boundary contacts reduced mean low frequency score AUC from 0.648 to 0.518 in two 120-second SEEG samples from each of 34 patients sci:sha256:e547ba318abd6b9a774f286ae12b241bb8a3240bcca44e3ea1611abd84bb2f29

    This work supplied the named boundary rule. It requires consecutive contact numbers on the same named shaft and opposite stable clinical onset labels. The present study applies that rule to gamma power spread in two 60-second records.

  2. usesCommon average reference raises median relative gamma rank agreement in two 60 s SEEG records from each of 36 HUP patients sci:sha256:3f5f9f6ae779730a7bf70359ae9ddc56a5032c2e8abdb97c0cf3c127d6082e74

    This work supplied the fixed 36-patient cohort, pinned 72-excerpt retrieval recipe, source metadata, EDF reader, and metadata selection check. This study retrieved the raw ranges again and computed new window power and spread features.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analysis used the HUP iEEG Epilepsy Dataset, OpenNeuro ds004100 version 1.1.3.

  4. doi:10.1002/hbm.25796
  5. doi:10.1038/s41467-024-52769-6

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.