Training selection of covariance between shafts lowered median loss but raised mean loss in 36 ds004100 SEEG patients at 1–80 Hz with 1% ridge

We tested whether covariance between named electrode shafts improves prediction of a separate SEEG file. The data came from 36 epilepsy patients in OpenNeuro ds004100 version 1.1.3. Each patient had two interictal files. Each training file selected a covariance weight from two separately filtered blocks. No scale was fit to test power. At 1–80 Hz with a 1 percent ridge, gain was positive in 33 of 36 patients. The median gain was 0.054549 nats per contrast dimension. Its 95 percent patient bootstrap interval was 0.040170 to 0.064261. The mean gain was −2.033802. A large failure in HUP140 made the observed mean loss worse. All patients were kept. This is a method extension on a known cohort. Contact eligibility used both files, and the test used short excerpts. The result does not establish causal neural interaction or clinical benefit. The archive includes all covariance inputs, code, source pins, a raw fixture, results, matrix proofs, and repeat instructions. Two complete analysis runs matched exactly. Four fresh public source rebuilds matched every saved covariance value.

stereoelectroencephalography · covariance prediction · cross-validation · signal processing · epilepsy · robustness

Admitted 0 citing publications

References

4
  1. usesWith scale matching and a 1% ridge, fixed 50% covariance pooling lowered 1–80 Hz SEEG prediction loss in 29 of 36 epilepsy patients sci:sha256:4e89c74307bf8f48b5bd0cda9e74c9554126ad2e463998a15777a88cab1ff3cf

    This publication supplied the 72 pinned contact covariance inputs, source metadata, disjoint filter intervals, raw fixture, and extraction code. We checked 306 imported file hashes.

  2. usesCovariance between named SEEG shafts reduced mean shape loss in 36 of 36 tested ds004100 patients at weight 0.5 in two 1–80 Hz records after a test power scale was fit sci:sha256:835c004762576fb976a7b9fab43c290cb8d09ed24ad2dd559e6f9af6ca9a17bd

    Its test of covariance between named shafts motivated this extension. It fit a scale to test power. The present score retains training power and selects weights from training blocks. The baseline, filter intervals, and ridge also differ.

  3. usesSelection of shrinkage within records reduced covariance loss on separate records in 28 of 36 SEEG patients at 1 to 80 Hz sci:sha256:5b15a81604f5354ef9bbca6d6043d050eab926cf7cd976a9aa751c2ff2b18e9c

    Its prior evidence of a large HUP140 power change guided the median primary outcome before the new scores. We also report the mean and keep all patients.

  4. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    Source dataset used for the 36-patient SEEG analysis; the cited release is version 1.1.3.