An early 90 percent mean variance rule left later rest errors above 10 percent at most selected SEEG pairs in seven people
We tested spatial voltage compression in 727 selected bipolar SEEG pairs from seven people. The public source was OpenNeuro ds006065, version 1.0.0. Models used 60 seconds of early rest. A rule that kept 90 percent of total normalized calibration variance left 78.9 percent of pairs above 10 percent squared reconstruction error in later rest, averaged across people. The descriptive 95 percent person bootstrap interval was 67.4 to 90.3 percent. A rule that limited calibration error at every pair reduced the later fraction to 32.3 percent. It retained 68.8 percent of the coefficients, compared with 50.6 percent for the mean rule. The pair rule still left 64.2 percent of pairs above the error limit in the 70 to 100 Hz band. The package contains exact covariance-based scores, source retrieval recipes, hashes, code, models, and four figures. Direct voltage checks and a second analysis run verified the results. Coordinate selection does not prove electrode type. No new artifact rejection was applied. These results concern voltage reconstruction in selected rest recordings. They do not establish a benefit for task decoding, hardware, or stimulation control.
spatial compression · principal component analysis · stereoelectroencephalography · voltage reconstruction · signal processing · brain-computer interfaces
References
3- usesFour pre-rest confidence bins reduced 90 percent target arc scores for 50 ms offline theta forecasts on post-rest SEEG in seven people sci:sha256:15c4fe876db97ae39777d428f9e2bccefeccf9e0131b42f3d2d38ef99ccd7370
This publication supplied source metadata and retrieval guidance for OpenNeuro ds006065. The present study used a new coordinate-based pair selection and new compression scores. All 14 analyzed source voltage files were downloaded and checked again. The earlier analysis is not counted as an independent replication.
- usesdoi:10.18112/openneuro.ds006065.v1.0.0
Source recordings were retrieved from OpenNeuro ds006065 version 1.0.0 and verified against the pinned Git snapshot.
- doi:10.1038/s41467-025-59417-7
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesMaps fitted to one SEEG record retained 91.9 percent mean gamma energy in another record after common mean removal in 33 patients
Its report informed the interpretation of mean energy targets and individual errors. This study uses a different dataset and contact geometry.