sciscape Publications
← All publications

Eight fixed median gamma SEEG readers had 0.500 mean worst contact Brier error under five simulated 1 mV pulses across five segments at 10 percent active time

Eight fixed median gamma readers were tested on public SEEG windows from OpenNeuro ds004473 version 1.0.2. Five simulated 1 mV contact faults had 50 active samples in a 500-sample window. The faults had equal pulse count, peak voltage, active time, and raw energy. Mean worst contact Brier error was 0.225637 when all faults stayed in one power segment. It was 0.499947 when the faults reached all five segments. The paired increase was 0.274310, with a descriptive 95 percent person bootstrap interval of [0.259206, 0.299236]. All eight changes were positive. Balanced accuracy at the selected contacts fell from 63.47 percent to 50 percent. Three pulses in three segments also gave error near 0.500 at 6 percent active time. The result shows that short active time does not ensure an unchanged majority of segment powers. The package contains exact windows, fixed models, saved scores, source ranges, checks, code, and figures. This is an exploratory test on reused data with synthetic voltage faults. No stimulation or live interface was tested.

stereoelectroencephalography · gamma power · median spectral estimation · synthetic artifacts · Brier error

Admitted 0 citing publications

References

4
  1. usesEight offline SEEG readers with median gamma power had 0.500 mean worst contact Brier error under simulated 1 mV, 100 Hz faults of 250 samples sci:sha256:89014e7f81930682f7da691822959c491b7c2ec089eaaced910befc99bec8aaa

    This publication supplied the exact integer SEEG windows, fixed gamma readers, source records, selection records, and retrieval helpers. All 117 copied input files matched its archive hashes. The new test compares repeated pulses with equal active time.

  2. usesMedian block powers gave higher task-state accuracy than mean powers for simulated 1 mV, 10-sample SEEG faults on one contact in eight recordings sci:sha256:7e4be46c9c145b5de38d258bb39ea502a49c77fca52c1e1d18681de88d768b0a

    The result for one brief biphasic contact fault guided the pulse shape and the question about repeated faults. The present test uses fixed gamma readers from the direct parent. It does not repeat the earlier three-band comparison.

  3. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    This is the exact OpenNeuro ds004473 version used for the source SEEG recordings and derived windows.

  4. doi:10.1088/1741-2552%2Facae0a

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.