Separate 30 second corrections reduced mean error from a 5% high gamma crossing rate in three SEEG recording pairs
We tested a short correction for a power threshold in public SEEG data. We used six records from three people in OpenNeuro ds003848 version 1.0.3. The test used 156 adjacent contact pairs and later data that did not set the correction. The power band was 70 to 110 Hz. Each starting threshold had a 5% calibration reference. The equal-person mean absolute rate error was 10.28 percentage points with the fixed threshold. It was 10.57 points with one shared median correction. It was 5.52 points with a separate median correction for each pair. The separate correction reduced error in 2 of three people. The records cover rest to sleep, sleep to a sleep-wake transition, and sleep to sleep. These data have no intended-command labels. The result measures numerical threshold stability. It does not show better task decoding or a safe stimulation rule. The package has code, features, raw examples, source versions, byte hashes, tables, and five figures.
SEEG · intracranial EEG · brain-computer interface · threshold calibration · high gamma · median correction · signal processing
References
5- usesA 20-second median correction reduced error for a 10 percent beta threshold target in saved SEEG records from seven people sci:sha256:0ab6c409a66046bcd1ce14f9afb3c5e51588bbaa620f40f8d19b1e8991247965
Its beta results helped interpret sensitivity to calibration duration. This study uses different data and fixed intervals of 10, 30, and 60 seconds. No code or signal arrays were reused.
- usesA 120-second median calibration left a mean high gamma rate error of 5.1 percentage points for a 10% target in eight SEEG session pairs sci:sha256:878731c694843c59980d6304a735b1a04b5ce68504f08fef057fdf9c73485346
Its direct new-session percentile reference informed the added secondary comparison. Its high gamma results helped interpret finite calibration limits. No code or signal arrays were reused.
- usesPulse pooling reduced observed normalized error for centered SEEG forecasts at 20–500 ms after contact order reversal in two recordings sci:sha256:66df9cc13a420195d9501065f94ea3680760f148fb924cb0c172624e64534ace
Its contact-type and source metadata audit helped identify the three SEEG participants. This study retrieved its own metadata and new raw ranges.
- usesdoi:10.18112/openneuro.ds003848.v1.0.3
Source dataset, exact version used for the six SEEG records.
- doi:10.1007/s12021-022-09567-6