Unreviewed veto calibration raised crossing excess by 8.45 points in 23 SEEG sleep records with a fixed reader
We tested whether a low-frequency voltage veto keeps its benefit when its limit uses calibration without discharge review. We used public SEEG sleep voltage from Falach and colleagues, Figshare 26131978 version 3. We kept the high-gamma reader threshold fixed. In 23 people, 596 adjacent pairs, and 425 later expert labels, full-minute empirical calibration raised event-minus-background crossing excess by 8.45 percentage points relative to reviewed calibration. The 95% interval across people was 4.58 to 12.75 points. Matching calibration sample count did not remove this effect. A fixed median and median absolute deviation rule on log peaks reduced excess by 8.56 points relative to the empirical unreviewed rule. Its mean excess was 4.85 points, compared with 4.97 for reviewed calibration. This does not establish equivalence. The robust rule lost 0.65 points of controlled 90 Hz detections and 3.70 points when a 15 Hz signal was also added. These are test voltages, not intended BCI commands. A secondary test also used unreviewed high-gamma calibration. The source-voltage replay matched all 100 compact arrays exactly. The package contains figures, code, source hashes, metadata, feature arrays, full result tables, controlled trials, and replay checks. The evidence concerns short epilepsy sleep records. It does not show BCI task accuracy or stimulation benefit.
SEEG · intracranial EEG · brain-computer interface · signal processing · calibration · epilepsy · veto threshold · high-gamma power
References
4- A 4 to 30 Hz voltage veto reduced high-gamma crossing excess near discharge labels in 23 SEEG sleep records sci:sha256:283a02757bd4465ee8b9d13785228d19d33e113cc6e04a627dbed4c1288d8977
[Legacy relation: reproduces] The ungated and reviewed 99th-percentile veto reference calculations reproduced the parent event fractions, background fractions, crossing excess, 23-person count, and 425-label count exactly. The new study uses a different bootstrap seed and does not claim an independent cohort replication.
- usesA 4 to 30 Hz voltage veto reduced high-gamma crossing excess near discharge labels in 23 SEEG sleep records sci:sha256:283a02757bd4465ee8b9d13785228d19d33e113cc6e04a627dbed4c1288d8977
We used the MIT-licensed EDF reader and feature extraction code, fixed adjacent-contact descriptions, source member hashes, compact high-gamma and low-frequency feature arrays, and controlled voltage test rules. We retrieved the original source archive and checked all 216 member hashes. A new extraction from all 25 EDF files matched all 100 feature arrays. These inputs enabled the new comparison of reviewed, empirical unreviewed, and robust unreviewed veto calibration.
- usesdoi:10.6084/m9.figshare.26131978.v3
This Figshare version is the recorded byte source for the SEEG sleep recordings used in the analysis.
- doi:10.1038/s41597-024-04187-y