Fitting on other patients chose zero added distance shrinkage for later 1–80 Hz SEEG covariance shape at a 10% ridge in 36 patients
We tested whether contact distance improved later SEEG covariance shape after 25 seconds of local calibration. We used two interictal files from each of 36 epilepsy patients in OpenNeuro ds004100 version 1.1.3. The models used a fixed 10% ridge. We tested six shrinkage weights and five Gaussian distance lengths. Each test fold fitted settings on the other 35 patients. Both model families chose zero added shrinkage in all 36 primary folds. The mean gain was zero nats per contrast. A refitted bootstrap of 20,000 patient resamples gave a 95% interval of −0.02276 to zero. At a fixed weight of 0.5, distance had lower loss than independence in 35 patients. The same fixed distance model had higher loss than the selected zero-weight model in 34 patients. Thus, the tested distance family gave no primary gain after the comparator was fitted. This result is limited to the tested grid, ridge, blocks, and reused cohort. It does not show that distance has no signal information. All 72 inputs were rebuilt from pinned public raw bytes and matched the archived arrays exactly. The package preserves the data, raw example, source metadata, code, fitting decisions, uncertainty draws, results, and reproduction instructions.
stereo-electroencephalography · covariance prediction · spatial prior · distance kernel · shrinkage · epilepsy
References
3- usesWith scale matching and a 1% ridge, fixed 50% covariance pooling lowered 1–80 Hz SEEG prediction loss in 29 of 36 epilepsy patients sci:sha256:4e89c74307bf8f48b5bd0cda9e74c9554126ad2e463998a15777a88cab1ff3cf
This study uses the fixed 36-patient cohort, all 72 contact covariance files, source metadata, raw byte recipes, and unchanged source tools from this report. We rebuilt all files from the pinned public bytes. The new analysis tests a supplied-coordinate distance prior.
- usesAfter signal and shaft pair controls, 1–80 Hz bipolar SEEG correlation magnitude between shafts had negative fitted coordinate distance slopes in all 36 tested epilepsy patients sci:sha256:c00ccb31868a25e0564b56ac6efac067acd957bb3bfeb7e0e5f340e3618bbca7
The reported distance slopes in the same 36-patient cohort motivated a prediction test. We tested whether a Gaussian distance prior improved later covariance shape after local calibration. We do not treat this reused cohort as an independent replication.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The study analyzes the 36-patient cohort and source data from OpenNeuro ds004100 version 1.1.3; the archived retrieval records preserve the exact byte hashes.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.