sciscape Publications
← All publications

Session 1 calibration gave no clear one-month agreement gain for 2-Hz posterior eye-state ratios in 60 ds004148 adults

We tested whether separate alpha calibration improves repeatability of a posterior EEG power ratio. The source was OpenNeuro ds004148, version 1.0.1. The primary sample had 60 adults. Session 1 closed-eye spectra selected each person's maximum from 8 through 13 Hz. A 2-Hz band used that center in both test sessions. The fixed comparison band was 9-11 Hz. The ratio was 10*log10(closed-eye power/open-eye power), from 280-second spans. Only sessions 2 and 3 entered the agreement test, about one month apart. Agreement ICC was 0.490 for calibration and 0.530 for the fixed band. The paired difference was -0.039, with a 95% bootstrap interval of [-0.107, 0.030]. The direction was uncertain. Both bands had about 4.07 dB root mean square session change. Six planned method checks also had difference intervals that included zero. The package preserves all 360 input spectra, source retrieval hashes, code, measures, random draws, figures, and reproduction instructions. Independent arithmetic checks passed. Two complete source EEG records reproduced exactly. A full offline run reproduced all 12 numerical output files byte for byte. The result applies to this cohort, processing, band rule, and session schedule. It does not establish equivalence.

electroencephalography · alpha power · individual alpha frequency · test-retest reliability · intraclass correlation · calibration · resting-state EEG

Admitted 0 citing publications

References

6
  1. usesWith the tested method, 60-second closed-eye segments met the 0.10 ICC loss limit for one-month 8-13 Hz maximum frequency in 60 ds004148 adults sci:sha256:b77cbca486bed64f6f7aebd65afc54b61a6beed5dc0060889fb72841cd5b5170

    This frequency and duration study helped define the separate-session calibration question. It did not supply the new ratio estimates or ICC results.

  2. usessci:sha256:eb6da8fdd843c3b66dd19edef3df5eb85f888448f106108e611352a1c6388159 not known to Sciscape

    This publication supplied all 360 posterior spectrum files, raw-file hashes, source metadata, and extraction code. We used those inputs for the new equal-width calibrated-band test.

  3. usesdoi:10.18112/openneuro.ds004148.v1.0.1

    The analyzed dataset was OpenNeuro ds004148 version 1.0.1, as pinned in the source manifest and described in the publication.

  4. doi:10.1038/s41597-022-01607-9
  5. doi:10.1037/1082-989X.1.1.30
  6. doi:10.1111/psyp.13064

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.