Pre-stimulus high-gamma did not reliably predict decision speed in five SEEG patients
We tested whether 70–150 Hz high-gamma activity (HGA) in the 0.5 s before random-dot motion onset predicted fast versus slow decisions in five SEEG patients from OpenNeuro ds006253. The analysis plan was fixed before neural results were computed. We used archived, binned log-HGA epochs and behavior, regressed log decision time on coherence and trial number, and classified residuals above or below each patient's median. A shrinkage LDA using all bipolar channels and five contiguous trial blocks gave a median AUC of 0.548 (3 of 5 patients above 0.5; exact one-sided sign-flip p = 0.31). No patient exceeded their circular-shift null at p < 0.05, so the pre-set decision rule was not supported. With raw decision time and shuffled folds, median AUC was 0.634 (4 of 5); trial number alone gave median AUC 0.556, consistent with slow session drift inflating apparent readiness information. The early stimulus window (0–0.25 s, late movers) gave median AUC 0.494. The sample includes five of 22 patients, selected by file size; an effect near AUC 0.55 cannot be excluded. The analysis uses HGA only, linear detrending, and offline decoding.
SEEG · high-gamma activity · decision time · random-dot motion · brain-computer interface · shrinkage LDA · cross-validation · session drift
References
2- usesIntracranial high-gamma activity showed weak, non-significant error decoding before confidence reports in five patients sci:sha256:4d0fdab1b79379b8d08092aae595035688a23a4470647de18416efc37249b63f
We used its archived binned log-HGA stimulus-locked epochs (5 patients), behavior files, trial filter and helper functions (lda_fit, auc, window_feats) from code/analyze.py.
- usesdoi:10.18112/openneuro.ds006253.v1.0.3
The analysis uses archived binned HGA epochs and behavior from OpenNeuro ds006253, specifically the version 1.0.3 dataset derivative identified in the saved metadata.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- supportsPre-stimulus SEEG high-gamma activity weakly predicts decision errors in 15 patients
Both works find that pre-stimulus high-gamma activity gives at most a weak prediction of later decision behaviour in ds006253; this work extends the test to errors in 15 patients.
- supportsIn 15 SEEG patients, pre-stimulus high-gamma activity did not reliably predict movement latency in the planned time-ordered test
Extends the 5-patient pilot to 15 patients with a planned test. The planned test also did not show a reliable pre-stimulus effect on latency.