Selection for retained template energy gave no clear 100 to 500 ms AUC gain after known simulated shaft loss in seven SEEG sessions at eight contacts
We tested whether a rule that selects recording pairs for retained template energy improved later SEEG response reading after one known simulated shaft loss. The source was public OpenNeuro ds004696 version 1.0.1. Seven epilepsy sessions supplied 79 stimulation sites and 395 separate test pulses. Each panel used four pairs and eight distinct contacts. Five early pulses set pair selection, a mean template, and diagonal noise weights. Five later pulses tested each intact and shaft loss case. The primary window was strict 100 < t < 500 ms. With equal patient weight, mean lowest AUC was 0.7825 for total-energy selection and 0.7835 for retained-energy selection. The difference was +0.0010; the descriptive 95 percent patient bootstrap interval was -0.0014 to +0.0035. The exact two-sided patient sign-flip value was 0.50. These data show no clear gain and do not prove equal performance. The release contains all selected panels, scores, loss cases, figures, a buffered reader, and a source retrieval recipe. A fresh source replay checked one patient. The loss was simulated. The AUC separates pulse-aligned voltage windows and does not prove neural origin or live BCI benefit.
SEEG · electrical stimulation · brain-computer interface · shaft loss · matched-template reader · AUC · OpenNeuro
References
4- usesA fixed spatial noise rule gave no clear 20 to 500 ms AUC gain after five early pulses in eight SEEG sessions sci:sha256:48f93098d9fe4ee439817f49e745f4c586103d8b79d4985cbb51b1bf7dc5d020
Used its exact pulse products, fixed recording pair tables, source metadata, source audits, and retrieval code to test four-pair selection under known shaft loss.
- usesSelection for surviving task utility gave no clear gain in lowest later accuracy after known simulated shaft loss in eight SEEG recordings at 16 contacts sci:sha256:51044e72b0a50774d7af9edd15ba381c1e7d14d64da23c332ca1de7d2df2828f
Used its grouped-loss selection design as method context. This study tests template energy and later pulse-window AUC in a different SEEG dataset at eight contacts.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
The analyzed public source was OpenNeuro ds004696 version 1.0.1; its version-pinned dataset metadata records this DOI and CC0.
- usesdoi:10.1523/JNEUROSCI.2201-22.2023
This is the source study for the public SEEG stimulation data analyzed here.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesSelection on two shafts increased SEEG shape retention after simulated worst shaft loss at 82 sites in eight recordings
This earlier work tested selection for retained template energy after shaft loss in the same source cohort at eight contacts. It supplies prior method context. The present endpoint uses signed shape matches at four contacts. This publication was reviewed after the primary analysis; no selection or endpoint changed.