Label-free prior correction did not significantly reduce movement-detector log loss in 15 SEEG patients
In an offline second-dataset test, we evaluated label-free prior correction for a shrinkage LDA detector of movement versus rest from 70–150 Hz SEEG high-gamma features in 15 patients. We calibrated on the first 60% of trials and simulated test batches at movement prevalences 0.5, 0.2, 0.1 and 0.05 using 200 draws per patient and prevalence. At prevalence 0.1, EM correction changed mean log loss by −0.044 nats per window (13/15 patients improved; exact sign-flip p = 0.88), and adjusted-count correction changed it by −0.113 (12/15; p = 0.051, Holm p = 0.10); neither confirmatory result was significant. With no prior shift, EM and adjusted-count correction increased log loss in all 15 patients. The oracle correction using the true prior decreased log loss in all 15. Corrections increased precision and decreased recall. Some label-free prior estimates were near zero and caused large losses, including a +1.53 nat increase for EM in one patient. This offline, simulated label-shift study covers one task and dataset; its results do not establish performance in continuous self-paced use, where class-conditional feature distributions may change.
SEEG · brain-computer interface · prior correction · label shift · log loss · movement detection · high-gamma activity
References
3- supportsEM prior correction did not improve log loss in an offline simulated key-press study of 8 SEEG subjects sci:sha256:f43be22890de83460644733c15556b594d246b78eb54246292b8fd1701b5aa6f
Same log-loss primary endpoint in a second dataset: EM - U not significant (p = 0.88), oracle prior better in all patients, EM worse in all patients at prevalence 0.5.
- supportsAt simulated 10% movement, EM prior correction reduced SEEG detector error by suppressing detections sci:sha256:2d2b47282fbbac70be1bea961bbcc9a75486b343ddb84b8fa9f6e8fee294e90e
Second dataset (ds006253, 15 patients): label-free EM prior correction again did not significantly improve probabilities at prevalence 0.1, and it was harmful with no shift.
- usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375
Archived 70-150 Hz HGA window features of 15 ds006253 patients and the shrinkage LDA code.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.