In six SEEG patients, polarity reversal slightly reduced CCEP similarity, and mixed-tissue pairs evoked more responses after distance control
We examined whether reversing monophasic single-pulse polarity changes cortico-cortical evoked potentials (CCEPs), and whether stimulation-site tissue predicts responses after distance control. We analyzed one SPESclin run from each of six patients in OpenNeuro ds005448 v1.0.0: 184 contact pairs with at least one responsive channel. For N1 waveforms (15–100 ms), same-polarity similarity was r = 0.322 and reversed-polarity similarity was r = 0.270 (difference 0.052, 95% CI 0.004–0.122); four of six patients had a positive difference. The late-window difference was 0.035 (95% CI 0.003–0.079), positive in all six patients, and was the only primary result with patient-level exact p < 0.05 (p = 0.031). Two patients contributed most of the N1 effect, while repeat similarity was low (r about 0.3), so trial noise was much larger than the polarity effect. In a distance- and patient-adjusted logistic model, pairs with a white-matter-labelled contact (score 0.5) had higher response odds than gray-matter pairs (odds ratio 2.28, 95% cluster-bootstrap CI 1.54–3.34). The within-patient rank test without distance adjustment was not significant (4/5 positive, exact p = 0.375). There were no pairs with both contacts in white matter. Results are limited to six of eight patients, one run per patient, five pulses per polarity, monophasic 1–2 mA stimulation, threshold-based detection without visual review, and dataset tissue labels that were not checked against imaging. The possible long-range tissue effect was not distinguished from volume conduction or residual artifact.
SEEG · single-pulse electrical stimulation · cortico-cortical evoked potentials · pulse polarity · white matter · intracranial EEG · OpenNeuro
References
2- usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3
We used and extended its byte-range retrieval method for ds005448 SPES windows (fetch_epochs.py) to read 6 patients without full-file download.
- usesdoi:10.18112/openneuro.ds005448.v1.0.0
The analysis used SPESclin data from OpenNeuro ds005448 v1.0.0 (STReEF), including one run from each of six patients.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesOpposite-polarity decoding identified 10 SEEG stimulation sites above chance at 10 mm in eight patients
That study found that reversed polarity changes CCEP waveforms only slightly. We used this as the basis for the opposite-polarity template control, which removes the sign-changing artifact but keeps most of the neural response.
- supportsSpearman-Brown predicts 17 pulses for reliable SEEG CCEP maps in eight patients
We also found that same-polarity single pulses give more similar maps than mixed-polarity pulses (+0.097 r for all channels, +0.051 for channels 15 mm or more away). We also found that the second, reversed-polarity block had a larger response in 8 of 8 patients.