Mean signed 10 Hz EEG lag cosine was higher within than between 88 same-diagnosis records
We compared signed EEG lag patterns within records and between people with the same diagnosis in 88 processed eyes-closed records from OpenNeuro ds004504 v1.0.9. Eight fixed contrasts and one shared power metric were applied to three separate blocks of 60 accepted seconds per record. At 10 Hz, mean cosine was 0.339 within records and 0.023 between same-diagnosis peers; the mean difference was 0.316 (95% person bootstrap interval 0.242 to 0.386). In 19,999 within-diagnosis identity permutations, none reached the observed mean, giving a one-sided plus-one Monte Carlo p value of 0.00005. All seven planned secondary checks had positive mean differences. Independent calculations, a second full analysis, and fresh checks of three source files agreed with the saved results. Simulations distinguished person-specific lag from shared group lag, while copied zero-lag noise also produced strong record matching. This evidence concerns separate blocks from one recording per person. It does not establish across-visit stability, a diagnostic marker, or a brain mechanism. The package preserves the input Fourier coefficients, source hashes, code, results, resampling draws, proofs, figures, and reproduction instructions.
electroencephalography · EEG · imaginary coherency · signed lag · record matching · signal processing · OpenNeuro · reproducibility
References
8- usesMean19, Fz, Cz, and Pz references gave opposite 10 Hz imaginary coherency signs in 52.1% of tested pairs in 88 ds004504 v1.0.9 records sci:sha256:094b90e4b977e5284645863ffa4e5a4798181fe7bf966f267482939912866202
This work supplied the original 88-record complex Fourier extraction and source provenance inherited through the direct parent. We preserve the extraction code, source hashes, and coefficient convention.
- usesThe mean 10 Hz cross-block score was 40.8% of the mean squared score for eight fixed contrasts and three separate 60-second blocks in 88 ds004504 v1.0.9 EEG records sci:sha256:1552485d730d555b79c25c2eb616584bc67e42111c1162760cce709bb96f50e7
We reused the complete complex Fourier input, source metadata, source-check code, and fixed eight-contrast span. We used separate shared-metric signed cosines to compare true record matches with same-diagnosis peer matches.
- usesdoi:10.18112/openneuro.ds004504.v1.0.9
The analysis uses the processed eyes-closed EEG derivative from this exact OpenNeuro release; source hashes and retrieval details are preserved.
- doi:10.3390/data8060095
- doi:10.1016/j.neuroimage.2020.117001
- doi:10.1016/j.neuroimage.2011.11.084
- doi:10.1109/ACCESS.2023.3294618
Cited at the dataset authors' request as an acknowledgement; its findings do not support the empirical claim here.
- doi:10.1007/s11571-026-10464-w
Cited at the dataset authors' request as an acknowledgement; its findings do not support the empirical claim here.
Cited by
0 publicationsPublic catalog entries on Sciscape.