In three SEEG patients, 3 mA increased CCEP map size and reliability over 1 mA without extending measured reach
This archived analysis compared single pulse cortico-cortical evoked potential (CCEP) maps at 1, 2, and 3 mA in three patients with stereoelectroencephalography (SEEG). It used 10 CHOCS1 pulses per current at 63 stimulation pairs from OpenNeuro ds003848 v1.0.3. Of 3,589 site-by-recording-pair combinations, median responders per stimulation site increased from 3 at 1 mA to 8 at 3 mA at z > 8, and split-half map reliability increased from Spearman rho 0.10 to 0.30. The gain was largest within 25 mm. Newly detected pairs at 3 mA were not farther from the stimulation pair than responders at 1 mA (median 31.3 vs 31.1 mm, p = 0.85). Baseline standard deviation was stable (3/1 mA ratio 1.01), while the 2–8 ms stimulation artifact increased 2.06-fold. These findings are limited to three patients at one center. Currents were delivered in blocks, with 1 mA first, so current is confounded with time. Only 10 pulses and a 90 ms baseline were used; the z > 3.4 threshold produced many apparent responses at long distances, and there were no expert N1 labels. The evidence supports stronger and more repeatable measured responses at higher current in this sample, but does not show greater response reach or establish a general current requirement for a brain-computer interface.
stereoelectroencephalography · cortico-cortical evoked potentials · electrical stimulation · current dose · map reliability · brain-computer interface · OpenNeuro
References
3- usesOnly 10 of 34 audited OpenNeuro iEEG datasets had SEEG-typed channels; only two had SEEG in almost all subjects sci:sha256:acebaa9155a622379563f108b3dd9bd3621f3e2dfd2ead35cba6f376dd0b4ec4
The audit identified ds003848 as an SEEG dataset with no publication.
- supportsCCEP SNR maps agree weakly across two stimulation protocols in 45 SEEG pairs from two patients sci:sha256:08b4001807c2073541bb06242fcf4704a1b3252a8b24e603ab9a76b7e5bee1df
That work found low split-half reliability of 1 mA CHOCS1 maps in the same patients. Here, reliability is also low at 1 mA (rho 0.10) and increases at 2-3 mA. Thus, low SNR is a cause.
- usesdoi:10.18112/openneuro.ds003848.v1.0.3
The analysis used CHOCS1 SEEG data from OpenNeuro ds003848 v1.0.3.
Cited by
1 publicationPublic catalog entries on Sciscape.
- challengesIn one SEEG patient, 2 mA pulses preserved most 1 mA N1 responses and added farther responders
Here new N1 responders at the higher current were farther than kept responders (15.6 vs 12.1 mm, p = 2e-11) and the farthest N1 increased from 22 to 35 mm; different dataset, labels and currents.