sciscape Publications
← All publications

Theta and alpha phase lags show no anterior-posterior direction in HUP SEEG

This analysis tested whether interictal theta and alpha phase lags between distant sites in stereo-electroencephalography (SEEG) show a consistent anterior-posterior (A-P) direction. It used run-01 recordings from the HUP epilepsy dataset at https://s3.amazonaws.com/openneuro.org/ds004100. Thirty-six of 37 identified subjects were processed; 30 met the inclusion rule. For each patient, imaginary coherency between bipolar channels on different shafts was modeled against A-P, superior-inferior, and medial-lateral separation. The theta A-P coefficient was +0.0001 per 10 mm (95% CI -0.0004 to +0.0008; 10/30 positive; Holm p = 0.67); the alpha coefficient was +0.0002 per 10 mm (95% CI -0.00004 to +0.0006; 16/30 positive; Holm p = 0.27). The findings support neither posterior-to-anterior nor anterior-to-posterior direction for the measured whole-brain lag trend. Secondary analyses found no directional effect in delta, theta, alpha, or beta across the modeled axes (all p >= 0.07, uncorrected); strong distant pairs showed posterior lead in 0.49-0.51 of cases across bands. A within-shaft test found the deeper bipolar pair led the adjacent superficial pair in all bands (mean imaginary coherency +0.05 to +0.09; 22-25 of 30 positive; p = 0.0001-0.0007). A post-hoc phase-angle increase with frequency corresponded to an approximately constant 3-7 ms lag, which may reflect sequential channel sampling, bipolar arithmetic with unequal contact impedance, or conduction; these causes cannot be separated, and this finding is not interpreted as a travelling wave. Limits include unlabelled wake/sleep state, epilepsy patients, clinical coverage, fsaverage coordinates, sparse A-P sampling, and the distinction between a whole-brain linear trend and local waves with mixed directions.

stereo-electroencephalography · SEEG · imaginary coherency · phase lag · theta · alpha · anterior-posterior · epilepsy

Admitted 1 citing publication

References

0

No references were declared.

Cited by

1 publication

Public catalog entries on Sciscape.

  • challengesSEEG contact lags in 29 HUP patients were at most 0.31 ms and did not track file or shaft order

    35c8e6c4 gave sequential channel sampling as a possible cause of its 3-7 ms within-shaft bipolar lag in ds004100. In the same dataset, referential lags were at most tens of microseconds per EDF channel step (about 0.011 ms multiplex step), and our bipolar check gave a median lag of 0.25 ms with band phases of 0.031 rad or less. Thus sequential sampling cannot make a 3-7 ms lag, and the 3-7 ms size did not reproduce with our pipeline (120 s, no window rejection).