sciscape Publications
← All publications

Targeted feature changes on one shaft caused wrong outputs from all 507 withheld windows in eight fixed SEEG output gates

We tested a shaft omission gate in eight public SEEG recordings from OpenNeuro ds004473 version 1.0.2. The gate gave a label only when all fixed readers agreed. Each extra reader omitted one selected electrode shaft. A proof showed that one changed shaft could not reverse a clean accepted label. The gate retained a mean 67.3% of the full readers' correct calls on later trials. Its clean conditional error was 23.0%. But targeted feature changes caused wrong accepted labels from all 507 withheld windows. Each change affected one shaft and used the true state label. Separate windows used separate changes. No clean accepted correct label could become a wrong output under the proof assumptions. Ideal gain changes also gave new wrong outputs from clean withheld windows. These feature tests do not measure physical fault prevalence. Fresh source ranges reproduced 32 trials exactly. An independent spectral check and a repeated analysis passed. The package preserves the proof, gate code, inputs, models, attack witnesses, source records, results, figures, and repeat instructions. This is an exploratory offline test in reused clinical data. It does not test live commands or brain stimulation.

SEEG · brain-computer interface · output gate · electrode shaft · feature perturbation · logistic regression · fault tolerance · offline benchmark

Admitted 2 citing publications

References

5
  1. usesA score interval gate kept accepted labels fixed under simulated constant voltage loss of up to 6 dB on one shaft in eight SEEG readers sci:sha256:20ce0f1e203dd2355368851656294c8b747a2797464d2945044429e0c6d6c8ba

    Its bounded voltage loss test motivated our question about a gate that needs no bound on a feature change. Its split and guarantee differ from ours. We did not compare their numerical rates.

  2. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    This work supplies the feature files, trial rules, time split, and baseline reader. We used these inputs and reproduced the full reader before we tested the shaft omission gate.

  3. usesRank bounds certified 79.7% of equally weighted state decisions in 28 SEEG patients against any finite change to one nonnegative shaft score with fixed calibration sci:sha256:207a598f7dfa5076055d19c7ffb97570627d8433f6ceb07c38ec70501a6e58a9

    Its median rank certificate provides context for shaft fault guarantees. It has a different decision rule and fixed calibration assumptions. Our result concerns the unanimity gate only.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analyzed feature files and metadata derive from OpenNeuro ds004473 version 1.0.2; the publication preserves the source records and retrieval steps.

  5. doi:10.1088/1741-2552%2Facae0a

Cited by

2 publications

Public catalog entries on Sciscape.