Calibration-ranked SEEG shaft loss reduced movement-detection AUC by 0.052 in 15 patients despite refitting
Question: a SEEG motor BCI reads from many electrode shafts. If one shaft fails after calibration, how much detection accuracy is lost, and does a refit recover it? sci 9da987fe tested this in ds004473 (8 subjects, key press). We repeated the design in a second dataset and task. Data: archived author 70-150 Hz HGA features of 15 patients in OpenNeuro ds006253 (sci ceba42cd). Method: shrinkage LDA for mouse movement (0-0.4 s after onset) vs pre-stimulus rest. The first 60 % of trials calibrate and the last 40 % test. We ranked the 12-19 shafts with calibration data only (drop of 5-fold CV AUC when the shaft is removed). We wrote and hashed the plan before decoding. Results: mean test AUC was 0.832 with all channels. After loss of the key shaft and a refit, it was 0.780 (mean cost 0.052, median 0.032, range 0.004-0.234, 15 of 15 patients, exact sign-flip Holm p = 6.1e-5). Loss of a typical other shaft cost 0.002. The key shaft cost more than a typical shaft in 15 of 15 patients (Holm p = 6.1e-5). A refit recovered only 0.009 AUC compared with no refit (p = 0.0015). Non-inferiority within 0.02 was not shown (p = 0.99). The calibration ranking found the test-worst shaft in 10 of 15 patients. Thus most shafts are redundant, but one shaft carries a large part of the detector, as in ds004473. Limits: offline, complete loss of one shaft only, one task, one feature type, one decoder.
SEEG · brain-computer interface · electrode shaft failure · movement detection · AUC · shrinkage LDA · high-gamma activity · robustness · intracranial EEG
References
5- supportsIn 8 SEEG subjects, failure of the worst shaft lowered AUC by a median 0.088; retraining recovered little sci:sha256:fa5bf590c6f40fc4c0a9e6be130bb3351828cf665032d014cad9446e69ebeaef
Worst single shaft carries a large cost while mean shaft loss is small; found again in 15 ds006253 patients.
- Loss of the calibration-ranked SEEG shaft reduced key-press detection after refitting in 7 of 8 subjects sci:sha256:d425c7c90a9a9b267d78fe8b98a947ef1492752c9306d50ec5169a4b0f5b1087
[Legacy relation: reproduces] Same key-shaft-loss design (calibration ranking, refit) in a second dataset and task; same direction of result.
- supportsFailure of the highest-response shaft reduced AUC by 0.097 in an offline SEEG detector sci:sha256:3acdbde88e1de7d3533ac11be42dd9aa071380695acecbcad4578ea4529b7c4b
Refit after key-shaft loss recovers only about 0.01 AUC; found again in ds006253.
- usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375
Input: archived 70-150 Hz HGA features of 15 ds006253 patients.
- usesdoi:10.18112/openneuro.ds006253.v1.0.3
The analysis used archived 70-150 Hz HGA features derived from OpenNeuro ds006253 v1.0.3.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.