The Pz target interval slope had a 95% interval that included zero in 10 eligible adults in ds003061 version 1.1.2
We tested whether time since the previous physical target predicts mean Pz voltage after a correct auditory target. We used all 39 EEG files from OpenNeuro ds003061 version 1.1.2. The rules were fixed before EEG measurement. The primary model used 2,130 trials from 10 eligible adults. The mean slope was 0.686 microvolts per interval doubling. The 95% Student t interval was -0.407 to 1.780. The exact sign-flip probability was 0.173828. This result does not establish a positive target interval effect. Baseline subtraction changed the mean slope from -0.550 to 0.686 on the same trials. These values do not identify the cause of the change. The package preserves code, source metadata, trial records, 28,425 Pz epochs, results, checks, and an exact raw-file retrieval recipe. All source files passed size and hash checks. A second offline analysis reproduced all eleven numerical result files exactly. The evidence applies to this sample, task, reference, filter, and trial selection. It describes association under the fitted model.
auditory oddball · electroencephalography · P300 · Pz · stimulus interval · stimulus history · public data · replication
References
4- usesBaseline correction left early leakage from 13 late EEG templates under a two-pass 1 Hz high-pass filter sci:sha256:d417e3b810768f0f95cdbcf7a22270e53cdb7c6684084eb8526bd629fc3d7761
We used the result that baseline removal can leave earlier filter output from constructed late EEG inputs. This result limits the interpretation of baseline voltage in our report. It does not establish the cause of the measured interval slopes.
- usesdoi:10.18112/openneuro.ds003061.v1.1.2
This is the exact OpenNeuro version used: all 39 raw EEG files, event tables, and metadata came from ds003061 v1.1.2.
- doi:10.1017/S0048577201393137
- doi:10.3389/fnhum.2016.00339
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesTargets had larger Pz minus Fz scores than noise at 300–600 ms in 12 selected adults from ds003061 v1.1.2
The prior package supplied source metadata, snapshot hashes, retrieval code, and event-history code. Its Pz waves were used to check a new extraction from all raw EEG files. Fz and reference waves were new measurements.
- usesCalculating history after correct response selection changed letter intervals in all 40 ERP CORE P3 records
Used its full stimulus history rule and its auditory history audit to design this separate visual event schedule test. No EEG files or code were reused.