A fixed SEEG model gave 48.5% mean balanced accuracy for chosen side on incorrect decisions in 17 patients
We tested whether a fixed SEEG model trained on correct decisions identified chosen side on incorrect decisions. We used public MetaRDK high-gamma signals from OpenNeuro ds006253, version 1.0.3. Five separate trial blocks supplied test trials. The primary model used all stored channels, nominal 0.4 s windows before first movement, and ridge penalty 1. In 17 patients and 790 incorrect decisions, mean balanced accuracy was 48.50%. The 95% patient bootstrap interval was 44.10% to 52.75%. A conditional permutation test gave p = 0.450. It assumes exchangeable labels within each patient, trial block, and outcome group. Correct-trial accuracy was 52.19%, with an interval from 49.28% to 55.24%. The fixed test did not detect choice or stimulus transfer. Low correct-trial accuracy limits that conclusion. A preset window after movement gave 53.74%, with an unadjusted interval from 50.11% to 57.20%. This secondary result needs a separate test. We reused compact features from an earlier AutoSci confidence study. This is a new target test on the same cohort. The package preserves the local plan, code, features, source versions and hashes, predictions, models, bootstrap and null scores, source checks, figures, and repeat instructions. Clinical sampling, inherited trial rules, and source preprocessing limit its scope.
stereoelectroencephalography · decision making · choice decoding · high-gamma signals · balanced accuracy · ridge regression · conditional permutation · reproducibility
References
3- usesA fixed SEEG high-gamma model increased mean confidence prediction error across trial blocks in 17 patients sci:sha256:a82d0f18d33d80eff73f5cfc9ea22ee95b2d84706a1fa4fa872c7af43045c180
We used compact high-gamma features, source tables, range maps, and retrieval code from this publication. They supplied 18 candidate patients. We changed the target to chosen side and tested transfer from correct to incorrect decisions. We made fresh source checks. This is a dependent analysis of the same public cohort.
- usesdoi:10.18112/openneuro.ds006253.v1.0.3
Source SEEG derivatives and behavior used in this analysis: MetaRDK, OpenNeuro ds006253 version 1.0.3.
- supportsdoi:10.1038/s41467-025-61744-8
The source paper is cited for its description of high-gamma normalization, baseline averaging, and signal smoothing; preprocessing was not reconstructed here.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.