Adding relative gamma power change did not raise within-shaft onset-label AUC in 15 test SEEG patients with two 60-second files
We tested whether relative gamma power change adds information for ranking seizure-onset labels. The base model used average gamma power and contact number. The source was public SEEG data from OpenNeuro ds004100 version 1.1.3. Each patient supplied two 60-second interictal files. The fixed split used 16 training patients and 15 test patients. Both models gave a mean within-shaft test AUC of 0.902431. None of the 472 tested comparison signs changed. A paired patient bootstrap fitted both models again in 5,000 draws. The 95 percent interval for AUC change was -0.013333 to 0.011111. The result does not establish equivalence or clinical benefit. All eight planned checks are reported. Fresh raw retrieval reproduced all 36 patient inputs and all 13 analysis outputs exactly. The package preserves code, window powers, labels, source records, raw retrieval recipes, results, and independent checks. This is a secondary analysis of reused patients, with an unknown time interval between files.
stereoelectroencephalography · SEEG · gamma power · epilepsy · within-shaft AUC · feature comparison · bootstrap uncertainty
References
3- usesWindow power normalization gave an onset AUC change interval that included zero for 30–80 Hz bipolar SEEG in 31 patients sci:sha256:dfeefad3c48d763517c278d3ef31d56413e449cd3e22f691ab285b86526d7b43
We used its exact paired window powers, retained contact lists, source metadata, retrieval recipe, and MIT signal code. Fresh raw retrieval reproduced all analysis inputs. These inputs enabled the new test of added information from gamma change between files.
- usesTime concentration gave no clear AUC gain for 80 to 150 Hz SEEG power with fixed linear models and independent resampling of 16 test patients sci:sha256:79076898607d7816bf22f29c086bea9adb9b3545752b18d0ddef86a6feeb9b6e
We read its ranking model comparison and its within-record high gamma concentration test before saving our plan. This work helped define the baseline comparison and distinguish the new test of relative gamma change between files.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The analysis used SEEG signals and clinical contact labels from OpenNeuro ds004100 version 1.1.3; the exact version and CC0 license are recorded in the saved dataset metadata.
Cited by
0 publicationsPublic catalog entries on Sciscape.