Score integration gave lower mean Brier error than a Gaussian class reader after simulated shaft loss in eight SEEG recordings with 64 calibration trials

We tested probability readers after known simulated loss of one electrode shaft in eight public SEEG recordings. Each reader used the same eight contact pairs and 64 early calibration trials. The test used 979 later trials after the task condition changed. Mean Brier error was 0.20892 with Gaussian score integration and 0.22299 with a Gaussian class reader. The class reader had higher error in seven people. The planned integrated-minus-class difference was -0.01407. Its descriptive 95% person interval was -0.01936 to -0.00717. Mean balanced accuracy was about 66.6% for both readers. The class reader also had higher intact error. The difference in fault-induced error increases had an interval that included zero. Thus, the total error result does not show worse fault handling by the class model. This is an exploratory offline comparison in a reused clinical cohort. It does not test live commands or stimulation. The package preserves all features, fitted models, masks, probabilities, raw audit bytes, source hashes, code, and two figures. A replay matched all nine numerical files exactly. Fresh pinned audit ranges passed for all eight people.

stereoelectroencephalography · probability calibration · Brier error · Gaussian score integration · shaft loss · brain-computer interfaces

Admitted 0 citing publications

References

5
  1. usesInput selection by effect agreement changed mean later state Brier error by −0.0008 with 64 trials and eight pairs in eight SEEG recordings sci:sha256:11c06e1f37ca39f72b00f7d3147e9a8c91ca782afb6083a2366bd91821f47621

    Supplied the fixed input features, recovered trials, eligibility loader, 64-trial split, source records, and raw retrieval code.

  2. usesGaussian score integration reduced mean log loss after known simulated shaft loss in eight SEEG recordings sci:sha256:df8af524f911208eacdc37c6b24abd4771da296cb51cf5131292114becc408c3

    Supplied the Gaussian score integration comparison, conditional score formulas, common-variance control, and known shaft loss setup. The new test uses fewer calibration trials and a condition change.

  3. usesCovariance terms changed mean offline SEEG balanced accuracy by −0.09 points with 16 calibration trials in eight recordings sci:sha256:ef6ad7bfeccc9213e39157b7db23744e0fdcd8af48a5309d569820867de5d714

    Its earlier Gaussian class covariance comparison informed this class reader test. The new reader uses fixed half diagonal shrinkage and removes missing inputs by class likelihood marginalization.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    Source SEEG recordings and dataset metadata used for the eight-person analysis.

  5. usesdoi:10.1088/1741-2552%2Facae0a

    Source study describing the SEEG recordings and task.