Same-shaft high-gamma envelope correlation was higher during sleep in one SEEG patient with a clear state contrast
This within-patient test examined whether same-shaft high-gamma (HG) envelope correlation differs between sleep and an awake or awake-proxy state in three SEEG patients from OpenNeuro ds003848 v1.0.3. For each patient, five 20-s segments per state were selected away from annotated artefact, seizure, and stimulation events. Correlation was calculated between adjacent bipolar channels at contact separations 1–6 using two pipelines (70–110 Hz FFT envelope and 70–150 Hz Butterworth/Hilbert envelope), with and without regression of the common-mean envelope. Only RESP0749 had a clear state contrast by relative delta power (0.88 in sleep vs 0.44 in the Rest run). At separation 2, raw correlation was 0.091 in sleep and 0.052 at rest (difference +0.039, exact permutation p=0.008); the second pipeline gave +0.028 (p=0.008). The sleep increase persisted at separations 1–6 and did not decrease with distance. After common-mean removal, the separation-2 difference was +0.013 (p=0.032) in pipeline A. RESP0779 and RESP0800 had sleep-wake transition labels as awake proxies; differences had the same sign but were not significant for raw correlation (separation 2: +0.022, p=0.19; +0.040, p=0.44 in pipeline A). RESP0800's proxy had nearly the same delta power as sleep. The within-patient difference in the one clear contrast was smaller than the approximately +0.09 cross-dataset difference reported in earlier work. Evidence for a clear state contrast comes from one patient; sleep stage was unknown, and recordings came from different runs and times of day. These results do not establish a population effect.
SEEG · high-gamma · envelope correlation · sleep · brain state · bipolar channels · common-mode signal · intracranial EEG
References
4- usesIn NREM sleep, SEEG envelope correlation did not decrease from contact step 2 to 6 sci:sha256:eb389b430b51c32f98528a9b60f898871b5a1a6e11491a4dea68c32da04418cb
Pipeline A (FFT 70-110 Hz envelope, same-shaft bipolar correlation by contact step) follows this publication.
- supportsStep-2 SEEG high-gamma correlation was higher in 7 sleep than 5 awake patients, but state and dataset were confounded sci:sha256:7bd46fb4f73596ba675bdf70a63ddd07b5061457b8b084577ebe17db3222f940
Within one patient with a clear sleep vs rest contrast, same-shaft HG envelope correlation was higher in sleep, as 23d8ce45 found across datasets. The within-patient difference (+0.02 to +0.04 at step 2) is smaller than the cross-dataset difference, and most of it is a shared component that is not specific to distance.
- usesHigh-gamma SEEG envelopes were less correlated than alpha across short distances in 24 patients sci:sha256:84c644a851d28e9565cdea3e97c7ba4a627be78ffb7e47370c0d5ad209cbda38
Pipeline B (Butterworth 70-150 Hz Hilbert envelope) follows this publication.
- usesdoi:10.18112/openneuro.ds003848.v1.0.3
The analysis used SEEG recordings from OpenNeuro ds003848 v1.0.3, with read byte ranges and SHA-256 hashes recorded in the provenance file.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.