Second harmonic phase terms increased later Brier loss for 50 ms theta confidence against offline targets in 17 SEEG rest files from seven patients
We tested confidence for 50 ms theta forecasts in 17 public hippocampal SEEG rest files from seven patients. The outcome was error at most 45 degrees against an offline 4 to 10 Hz reference. Each file used earlier data to fit probabilities and separate later data to test them. The baseline used forecast amplitude. Added terms used the second harmonic of forecast phase and its interaction with amplitude. Patient mean Brier loss increased from 0.236642 to 0.237731. Mean gain was -0.001089. Six patients had higher loss. The descriptive 95% patient bootstrap interval for gain was -0.001981 to -0.000406. The two-sided patient sign-flip p was 0.03125 under the stated null assumptions. All fixed sensitivity checks had higher mean loss. A marked post-plan calculation found lower calibration loss in every file. The test does not exclude other phase models or test a stimulation effect. The package preserves native inputs, source pins, code, fitted models, query predictions, inference draws, figures, and instructions. New downloads reproduced all 17 inputs. An offline repeat reproduced all analysis arrays and tables exactly.
phase prediction · Brier loss · confidence calibration · theta rhythm · SEEG · signal processing
References
5- usesEarlier amplitude calibration reduced later Brier loss for 50 ms theta forecasts against offline targets in 17 SEEG rest files from seven patients sci:sha256:804205cb81d8c2d8919fc7e6f10a86cf83022bc12f4cf9ebbada93fc61867e1b
This study uses the native voltage extracts, contact choices, time splits, source records, and signal forecast code. It reproduces the amplitude probabilities and tests added phase terms on the same later data.
- usesdoi:10.18112/openneuro.ds006065.v1.0.0
Source of the 17 rest-file inputs used in this analysis.
- doi:10.1038/s41467-025-59417-7
- usesdoi:10.5281/zenodo.14735080
Source study code archive used to confirm phase contact definitions; it is not the Python analysis implementation.
- doi:10.1088/1741-2552%2Fab8683
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesA past voltage ratio gate reduced 50 ms offline theta phase error in 17 rest SEEG files when each of seven patients was excluded from fitting and gate setting
Its known within-file confidence result informed the new question about a gate set with other patients. We did not import its code or data.