80 to 150 Hz power concentration gave a mean local ranking fraction of 0.759 across four consecutive contact numbers in 30 SEEG patients
We tested 80 to 150 Hz power concentration across contact label transitions in public SEEG. The data came from OpenNeuro ds004100 version 1.1.3. Thirty patients each supplied two 60-second interictal clips. We used 78 comparisons between onset pairs and other pairs in the same contact name group. The pairs used four consecutive contact numbers and shared no contact. The mean local ranking fraction was 0.759, with a 95% patient bootstrap interval of 0.666 to 0.842. The broad comparison kept the same onset pairs and used all eligible other pairs in their groups. Its mean was 0.705. The planned local-minus-broad difference was 0.054, with interval -0.004 to 0.111. The test did not establish a change. A later exploratory score based only on minus contact number gave a local fraction of 0.813. Concentration had no clear advantage over that score. Source coordinate units conflict with the numeric scale, so local means contact-number proximity only. Fresh source retrieval reproduced all 68 feature files exactly. The package preserves code, source labels and identities, input powers, comparisons, patient values, bootstrap draws, figures, plans, checks, and reproduction steps. These results assume independent patients for the intervals. They do not establish clinical performance or metric anatomical proximity.
stereoelectroencephalography · epilepsy · seizure-onset labels · high-band power · ranking fraction · contact topology · interictal recordings
References
3- usesTime concentration of 80–150 Hz SEEG power gave a mean AUC of 0.706 for seizure-onset labels in 34 patients with two 60 s clips each sci:sha256:1f5be9e5c88e4ff8065fcb38d242d64e32c8801f49e8f30af1fa36489bb1cf50
This study uses its unchanged 68 window-power files, 36 contact quality records, source metadata, pinned signal range recipes, and extraction code. They enabled the new four-contact comparison and the matched local and broad ranking test. All source arrays and quality records were rebuilt and checked.
- usesReference choice changed relative 30–55 Hz power AUROC by 0.111 on average in two 60 s clips from 35 SEEG patients sci:sha256:d441c426f62a09b3b78933ca35f4c191a45f8076d63d922c1013d1d697a54791
The inherited source_io.py module originated in this work. We use it to decode source EDF ranges and check contact and pair selection. Its exact copied hash is preserved.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source SEEG recordings and clinical seizure-onset labels from OpenNeuro ds004100 version 1.1.3.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.