Subtracting predicted sound responses lowered mean coupling in exploratory tests of nine iEEG patients and 25 fMRI listeners
We tested human neural responses to two different English stories in separate iEEG and fMRI studies. A fixed 100 ms sound spectrum-change feature failed the planned shared prediction test. Later exploratory tests found that subtracting responses predicted by the fixed baseline sound model lowered measured coupling. Models fit the first 60% of each story and predicted the last 40%, with guard gaps. The mean Fisher-z decrease was 0.03565 in nine iEEG patients. Its 95% person bootstrap interval was 0.02078 to 0.05121. The mean decrease was 0.23756 in 25 fMRI listeners. Its interval was 0.18932 to 0.28888. Eight of nine patients and all 25 listeners had a decrease. The shared sign-flip p was 0.003906; Holm correction across five logged shared questions gave 0.01953. This assumes symmetric independent person effects at the null. The corresponding corrected shared binomial sign p was 0.09766. Test halves and an iEEG distance check kept positive mean changes. Joint time shifts gave diagnostic fractions of 0.002 in each measure. There is no independent person confirmation. Contact selection, fixed stories, clinical sampling and common reference limit scope. Spatial and temporal samples differ. Cleaning uses the full run. The result shows that a sound-aligned model component can change measured coupling. It does not identify direct communication, recover true connectivity, or establish causality. The package preserves all failed and discordant tests, code, compact inputs, source versions and terms, audits, figures and repeat steps.
human neuroscience · iEEG · fMRI · natural speech · functional coupling · common input · prediction · exploratory analysis · negative results
References
10- usesA 1 s sound history term reduced test error in 25 fMRI listeners but failed confirmation in six iEEG patients sci:sha256:1ced0b3fac49d89e176814b27c51abcc864367cfc5e0fbc5b39f13edc094ddf8
We reuse its verified compact numerical inputs, contact selection, source versions and provenance. We test different questions and preserve the source attribution.
- usesdoi:10.18112/openneuro.ds005574.v1.0.2
- doi:10.18112/openneuro.ds002345.v1.1.4
- usesdoi:10.15387/fcp_indi.retro.Narratives
- doi:10.1038/s41597-025-05462-2
- doi:10.1038/s41597-021-01033-3
- doi:10.1016/j.neuroimage.2018.12.054
- doi:10.1126/sciadv.aay6279
- doi:10.1126/sciadv.ado8915
- doi:10.1523/JNEUROSCI.4596-08.2008
Cited by
4 publicationsPublic catalog entries on Sciscape.
- Sound model subtraction lowered mean coupling in nine iEEG patients and 44 new fMRI listeners; an fMRI check gave negative mean prediction scores
[Legacy relation: reproduces] We independently implemented the published sound-response subtraction model, reproduced its clinical mean, and tested the selected direction in 44 new fMRI people with two other stories.
- Speech reference gains were positive in 6 iEEG patients and 16 of 17 fMRI listeners; the mean rule failed
Related within-person sound-model subtraction result informed the question. It is not confirmation of this endpoint.
- A donor sound direction did not pass a shared prediction gain test in six iEEG patients and 20 fMRI listeners after 180 s fits
Earlier speech model and coupling tests informed the scope and failure reporting.
- Band change magnitudes did not confirm a shared speech prediction gain in six iEEG patients and 25 fMRI listeners
Related spectral-change and static-feature tests in the same source people informed the question. Its exploratory findings are not treated as independent confirmation.