A waveform shape score gave no clear gain in the call gap at 85 selected SEEG sites in eight people with five fit pulses and 20 to 500 ms windows

We tested whether division by waveform length improved a fixed pulse feedback score in OpenNeuro ds004696 version 1.0.1. The main test used 425 later pulses at 85 selected SEEG sites in eight people. Each site used five earlier pulses to fit a shared template and separate score thresholds. After windows covered 20 to 500 ms. The shape score changed the after-call rate minus the before-call rate by -2.06 percentage points, with a descriptive 95% person bootstrap interval of [-5.38, +1.13]. Thus, it gave no clear gain at the recorded voltage scale. It reduced after calls by 3.80 points and before calls by 1.74 points. AUC changed by +0.00188, with an interval that included zero. Positive test-voltage gains of 0.25 and 4 left shape calls fixed. These were software controls. The late-window control gave a larger call-gap loss. The test reused a selected clinical cohort and did not establish neural-response labels or live interface benefit. The package preserves exact voltage windows, scores, code, four figures, source records, and reproduction commands. All eight complete public processed source files passed fresh hash checks and exact waveform reconstruction.

stereoelectroencephalography · SEEG · electrical stimulation · waveform shape · feedback reader · call gap · gain invariance · brain-computer interface

Admitted 0 citing publications

References

4
  1. usesFive later pulses had 6.5 percent lower SEEG sample variation rank after stimulation than before it at 85 selected sites in eight people sci:sha256:96642184de3ffaee6e2915b82a5b2ae48d92a344b85dfab3cbfd23177be4ab33

    The source reconstruction code from this publication was carried through the immediate input package. We used that code to download all eight pinned processed MATLAB files and check every saved voltage window against the public source.

  2. usesSixty block means gave the same SEEG detection AUC as 960 samples on five later pulses at each of 85 selected sites in eight people sci:sha256:405201883414d702109e92cb19e43990240ed9b4363fe499c84941c63d980f8e

    This publication supplied the exact saved bipolar voltage windows, pulse metadata, selected contacts, duplicate-site exclusion, and inherited source records. We retained these inputs and tested division of a signed score by waveform length.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    Analyzed voltage windows and pulse metadata came from OpenNeuro ds004696 version 1.0.1; the cached dataset metadata records this exact version as CC0.