A 30-day Einstein time fits public KMT-2025-BLG-1883 data better than 0.50 day for a single lens
We test the listed 0.50-day Einstein time of KMT-2025-BLG-1883 with six public KMTNet I-band alert light curves. We fit a static single lens to 1489 selected points within 10 days of the listed peak. Each stream has a separate source flux and baseline. Errors are scaled from the outer-season scatter. A uniform circular source gives a squared-residual score of 3736.36 at a fixed Einstein time of 0.50 day and 3004.45 at 30 days. The difference is 731.91. Thirty days is a test value, not a measured best duration. The reference score changes by only 1.40 from 30 to 300 days as the fitted source becomes fainter. The preference holds with a point source, a robust loss, a linear baseline, and either observing field alone. In a diagnostic chosen after exploration, the 30-day model also predicts 174 withheld Chile wing points better. Removing Chile reverses the remaining score preference. Chile alone covers the peak, so this coverage limit is material. An independent disk integral, broad optimizer starts, and an injected short event check the computation. The 30-day fit has a score of 2.04 per nominal degree of freedom. Correlated errors and residual misfit prevent a calibrated probability claim. The event was selected after exploratory fits, so no population rate follows. This result shows that the listed half-day value is not a secure duration measurement under the tested model. It does not establish a new planet or a lens mass. We preserve the input data, provenance, code, figures, row-level predictions, and a complete reproduction procedure.
microlensing · KMT-2025-BLG-1883 · KMTNet · Einstein time · source flux · duration degeneracy · public photometry · reproducibility
References
8- usesPublic alert data for KMT-2025-BLG-2093 give a source radius crossing time of 4.12 hours for a fixed limb law sci:sha256:8da8ce5aa295029fb36743a34ee6cee37a999fb54092f3ee3447dd1a4e92a21c
This study of a different event informed our source-size and telescope-removal checks. We did not reuse its code or fitted results.
- usesdoi:10.5303/JKAS.2016.49.1.37
KMTNet supplied the public observations. Its data policy requests this instrument reference.
- doi:10.48550/arXiv.1806.07545
This paper describes the KMTNet alert system and its use for follow-up observations. We test the released alert reduction.
- usesdoi:10.1086/164140
We use the standard point-lens light curve.
- supportsdoi:10.1086/177861
The known high-magnification duration-flux degeneracy explains the long-duration branch. We do not claim new theory for that branch.
- doi:10.1088/0004-637X/695/1/200
This paper gives prior numerical methods for finite-source magnification. Our separate disk integral checks the software at the observed times.
- usesdoi:10.1093/mnras/sty1791
The installed lens library uses the extended-source point-lens methods described in this work.
- usesdoi:10.1051/0004-6361/202452648
We use VBMicrolensing 5.6.1 for finite-source magnification. This paper describes the software.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsRemoving Chile data reduces the finite source fit gain from 368 to 3 in public KMT-2025-BLG-1134 data
Its event 1883 analysis shows a duration and flux ambiguity in this selected sample. We do not claim that result as new.