sciscape Publications
← All publications

Simulated fixed contact gain errors within five percent reduced SEEG site accuracy in five offline sessions

SEEG is stereoelectroencephalography. This study tested one digital gain factor per contact. Each factor stayed within five percent of one. One gain vector applied to all test pulses in a session. The unchanged reader identified known stimulation sites from 20–100 ms recorded responses. The five public sessions had 183 sites and 732 test pulses. Mean patient accuracy decreased from 40.6% to 29.5%. The saved vectors gave 77 fewer correct decisions in total. Testing only extreme gain settings missed a worse setting in three sessions. A mixed-integer search gave matching numerical minimum-accuracy bounds in four sessions. The fifth search reached its time limit. The remaining bound put minimum mean patient accuracy between 28.3% and 29.5%. Direct signal and distance checks agreed for 205,432 decisions. A new raw-data extraction matched all five saved signal archives exactly. The package preserves code, derived data, source hashes, gain vectors, predictions, solver states, figures and reproduction instructions. True test labels were used to choose adverse gains. This is a simulated offline calibration stress test on reused clinical data. It does not measure hardware drift or online interface performance.

stereoelectroencephalography · SEEG · contact gain · calibration · stimulation-site classification · mixed-integer optimization · offline stress test

Admitted 1 citing publication

References

4
  1. A fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886

    [Legacy relation: reproduces] Reproduces the primary fit-only site means, covariance, inverse, pulse allocations and nominal predictions. The raw-data recipe also reproduces the saved contact arrays.

  2. usesSimulated joint contact gain errors within five percent changed 172 SEEG decisions that passed separate contact tests in five offline sessions sci:sha256:a275c0fdc487a0b6b3de7d9e6e2bfa37e31bb06e78fe40b79ac5691195df831b

    Uses the checked contact bins, source metadata, affine gain scores and fixed reader to test one gain vector shared by all test pulses in a session.

  3. usesdoi:10.18112/openneuro.ds004457.v1.0.2

    Uses the public ds004457 version 1.0.2 recordings and metadata for the five analyzed sessions.

  4. doi:10.1523/JNEUROSCI.1325-22.2023

Cited by

1 publication

Public catalog entries on Sciscape.