Recorded-zero STOP removal decreases the minimum number of response removals in 149 of 232 selected ds000030 version 1.0.0 runs.
In 232 paired UCLA Consortium for Neuropsychiatric Phenomics ds000030 version 1.0.0 task runs, removing recorded-zero STOP rows decreased the minimum number of further response-row removals needed to change the GO-versus-STOP mean reaction-time check in 149 runs (71 scanner, 78 training). It stayed the same in 75 and increased in 8; scanner sub-11052 changed from 24 to 54. Each run was evaluated before and after removing all STOP rows with StopSignalDelay == 0, then all permitted allocations of positive-reaction-time GO and STOP response removals were enumerated while omission and response-fraction rules remained satisfactory. Exact integer arithmetic retained source decimal values. A second independent program agreed on all 468,121 allocation limits, 663 minimum-allocation examples, paired records and summary counts; the code also matched the specified scope of 253 prior run rows. These are exact results for fixed recorded tables and specified rules, not biological causes, population estimates, or evidence of physical cue timing, model validity, repeat-session reliability, or sampling uncertainty. Removal is not recommended as data correction. The comparison excludes nine prior mean-check changes and two fraction-rule changes, and several caveats limit interpretation.
stop-signal task · reaction time · response removal · recorded-zero delay · reproducibility · UCLA Consortium for Neuropsychiatric Phenomics · ds000030
References
5- Nine mean RT checks change after recorded-zero row removal in selected ds000030 version 1.0.0 runs. Each reference mean is less than one. sci:sha256:bb9a5755e2a1b184df1f1d6bd4e52ee420f42e0c27e403e40cbcaac00f1d813a
[Legacy relation: reproduces] The source supplied the pinned files and comparison tables. New code agrees with all 253 baseline rows for response numbers, recorded-zero row numbers, three means, selection results, and the nine change identifiers. This relation does not cover the equal-size STOP removal reference or stopping-time estimates.
- usesRemoval of one response changes the result of the check of mean reaction time in 13 of 266 ds000030 files. sci:sha256:a16d31fbe42052ea69182ec444a4b05382719c5a76199a256ef6589fb204ebb6
The read description supplied the one-response removal method and the requirement to keep later records fixed. These enabled the multiple-response calculation. This relation does not reproduce the prior full cohort or nonresponse removals.
- usesdoi:10.18112/openneuro.ds000030.v1.0.0
This is the exact ds000030 v1.0.0 release identified by the source record and analyzed files.
- supportsdoi:10.7554/eLife.46323
The consensus guide supports the interpretation of early responses and choice errors in mean comparisons and the stated trial-count limitation.
- supportsdoi:10.1038/sdata.2016.110
The data descriptor documents the Stop Signal task design, including training delay values used to initialize scanner delays.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesNext STOP classes have no variation in full schedule-position cells from 126 ds000030 CONTROL scanner runs.
Its source files and checksums supply the 258 fixed input files for this audit.