sciscape Publications
← All publications

A one-second delay did not establish lower high-gamma deviation after detected periodic runs in 14 SEEG patients

We tested whether an added one-second delay reduced high-gamma power deviation after detected periodic voltage runs. We used 21 public SEEG records from 14 patients in OpenNeuro ds006519 version 1.0.0. Four detector checks agreed within one pulse period in these records. The test used two 0.5 s windows, selected harmonic bin removal, and a matched baseline control. Each patient had equal weight. The mean decrease after baseline correction was -0.307 dB. The 95% patient bootstrap interval was -0.736 to +0.050 dB. The exact two-sided sign-flip p value was 0.196, under independent patients and symmetric null contrasts. The fixed test did not establish lower deviation with the added delay. Other planned checks were also inconclusive. The package contains compact spectra, all scores, three figures, source hashes, and code. All 355 source files passed checks. Independent spectra and full and compact rebuilds matched the saved results. The detected run landmarks are not verified hardware stops. This test does not establish a safe read delay or decoder recovery.

SEEG · intracranial EEG · stimulation · high-gamma power · signal processing · baseline control · periodogram · brain-computer interface

Admitted 0 citing publications

References

4
  1. usesA fixed detector found periodic voltage runs in 31 of 35 SEEG records from ds006519 version 1.0.0 sci:sha256:ea4058aa1dce526e987cca14e771bbeab34ccf9025624ac6983dbb7c42876d8e

    We used its exact timing table, detector code, retrieval code, source manifest, and metadata. Its later agreement flags selected the primary sample. We rebuilt all 35 acceptance and agreement flags from native voltage. The sample is reused, not an independent replication.

  2. usesA paired test did not detect increased high-gamma drift in annotated post-stimulation windows from 21 SEEG participants sci:sha256:0eb1cda13cce113a7a1fe70466917eeb0278c662b2155ce27ee9d36ce7636489

    Its paired high-gamma drift test motivated a matched baseline control. Our test uses 0.5 s windows after detected run landmarks and measures the early-to-later decrease. We did not use its scores or code.

  3. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    This exact OpenNeuro release supplied the SEEG records analyzed in the publication.

  4. doi:10.1016/j.neuroimage.2026.121822

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.