Fixed atlas weights gave higher mean normalized error from 20 to 100 ms in five offline 6 mA SEEG sessions
We tested whether source contact atlas labels help predict a response at an excluded stimulation site. We used public SEEG data from OpenNeuro ds004457 version 1.0.2. The test had 52 sites in five patient sessions and fixed ventral temporal readouts. Each transfer model used the first four pulses at each immediate flank. It used no target pulses. The test used the last four target pulses. Equal weights gave mean normalized squared error 0.5832 from 20 to 100 ms. A fixed 2:1 atlas rule gave 0.5945. The mean skill change was -1.13 percentage points. The descriptive interval was -4.58 to +2.15 points. The exact sign-flip p value was 0.625. The rule changed weights at 17 sites. Reverse weights gave little mean difference. An exact error split showed little mean direction benefit from the atlas choice. The unnormalized voltage error had the opposite point direction. This result depends on the score and the readout set. The test is offline. Of 416 donor pulse roles, 200 occurred after the target test block. The package supplies a fixed benchmark, site errors, predictions, figures, code, source hashes, and raw retrieval commands. All 110 raw source files passed hash checks. A raw rebuild reproduced every compact array and event field exactly. A clean run matched all 14 numerical result files. The study reuses prior recordings. It does not establish a wider benefit or harm.
stereoelectroencephalography · electrical stimulation · ventral temporal cortex · response prediction · atlas labels · normalized error
References
5- usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886
This work uses its compact contact voltage bins, source metadata, fixed readouts, and raw extraction code. A raw rebuild reproduced all input arrays and event fields exactly.
- usesSEEG error products from 20 to 100 ms exceeded a before-pulse control in four of five offline 6 mA sessions sci:sha256:4aeb989ec5cc8154418690cd7d288f7a2f8e538c2ee009abb19d9fe0e8e75761
Its error audit motivated the 30 ms start control and the readout check with no shared contacts. The recordings are shared, so these are not independent patient data.
- usesTwo flanking sites reduced mean 20 to 100 ms error against shaft means in five offline 6 mA SEEG sessions sci:sha256:9b6afff9690f55fdc91733efdb076448378bba9931e59d409d71dbc71d40c98f
This work uses its 52-site flank test design and equal donor mean. It adds fixed atlas weights and reverse weights with the same donor pulses.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analysis uses OpenNeuro ds004457 version 1.0.2; its local dataset description and the recorded version-specific external metadata identify this exact version.
- doi:10.1523/JNEUROSCI.1325-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.