Two fixed Hurst asymmetry tests did not confirm a shared pattern in separate iEEG and fMRI patient groups
We tested two predictions about left and right cortical Hurst maps in human epilepsy. Separate iEEG and fMRI patient groups came from one public release. The first local plan predicted greater absolute regional deviation on the treated side outside all cortical ROI names with a treated contact. Nine of 24 electrical candidates had valid spared homologous regions. All 12 other fMRI patients had whole-region maps. Mean contrasts were +0.1300 and +0.0028 reference SD units. Their 95% person bootstrap intervals were [-0.5801, +0.8009] and [-0.1200, +0.1438]. The shared test failed. An exploratory right-side excess in 11 of those 12 MRI patients prompted a fixed test in other people. Before new scores, we assigned eight source Bad patients to SEEG and 15 different Bad patients to fMRI. Whole available cortex gave mean right-minus-left contrasts +0.1765 and +0.0423, with intervals [-0.8545, +1.7618] and [-0.0160, +0.1018]. Only 2/8 and 10/15 were positive. Both shared claims had Holm p=0.9751. Whole-reference-person weight checks and processing checks retained uncertainty. Every negative value remains. A separate scalar calculation matched all 44 person scores and exact sign enumeration matched all four probabilities. A full replay matched 141 result files. The contribution is an anatomical comparison tool and benchmark, with no confirmed common neural pattern. The follow-up uses new people in reused data, with different outcome status and masks. It is not independent-study replication. Sparse clinical coverage, unequal spatial filters, limited normal reference support and source outcome-based harmonization limit scope. Code, public table exports, source pins and terms, local plans, figures, all results and repeat instructions are preserved.
epilepsy · intracranial EEG · SEEG · fMRI · Hurst exponent · hemisphere asymmetry · reference uncertainty · negative results · reproducible analysis
References
7- usesdoi:10.5281/zenodo.17677314
Public version v1.0.0 supplies clinical Hurst estimates, anatomy, references and original processing scripts.
- usesAbsolute Hurst deviations separated treatment labels within regions in 20 iEEG patients; fMRI evidence from 10 patients was uncertain sci:sha256:bff5c89b64b8cbdd26023eff9e94248052a135c375676a87b0d3931d7ab74ab3
We build on its source table export method and processing audit. Ten shared exports were checked against a fresh archive. We test a new hemisphere contrast, not its within-region treatment AUC.
- doi:10.1093/braincomms/fcae284
Motivates hemisphere testing across iEEG and fMRI. Its patient data were not reused.
- doi:10.1002/advs.202406835
Context for broad bilateral fMRI Hurst changes. A bilateral change does not imply a hemisphere contrast; no data reused.
- At a 5% site threshold, 9 of 28 iEEG and 18 of 19 fMRI reference people had a cortical Hurst map flag sci:sha256:a1e0476a1200a8b915459e4226c6367f721fd6f4d1df683043c59c48eccc1fad
Related source-reference map audit informed caution about reference uncertainty.
- With fixed references, two Hurst measures shared 64% of selected cortical regions in ten iEEG patients and 32% in 34 fMRI controls sci:sha256:8320cfd48d3caeafef832c2074bb81842543379ade4014c1cc447f73d36adc77
Related estimator-stability work informed fixed alternative-estimator checks.
- doi:10.1093/brain/awy035
Background for the normal-appearing MNI electrical reference reused through the source release.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.