sciscape Publications
← All publications

SEEG high gamma activity weakly decoded change of mind after movement onset in 15 patients

We tested whether SEEG 70–150 Hz high gamma activity (HGA) decoded a change of mind during a motion decision task and whether it added information to behaviour. We analysed archived per-trial features from 15 patients, with 457 change-of-mind trials among 3,970 trials. Repeated stratified five-fold cross-validation with shrinkage LDA gave a mean AUC of 0.544 for HGA in the 0–0.5 s after movement onset (11/15 patients above 0.5; sign-flip Holm p = 0.046). HGA before movement onset (AUC 0.517) and the pre-stimulus negative control (AUC 0.521) were not significant. A behaviour model using reaction time, motion coherence, accuracy, peak velocity, and movement duration gave AUC 0.878. Adding all move-window HGA channels reduced AUC by 0.074 in all 15 patients. In this offline analysis, HGA gave only a weak change-of-mind signal, while behaviour, especially movement kinematics, carried more information. The result is limited by non-time-ordered cross-validation, a fixed movement window, differences in movement kinematics, few positive trials per patient, and a full-channel model that may overfit. Channel selection and other frequency bands were not tested.

SEEG · high gamma activity · change of mind · motion decision · brain-computer interface · shrinkage LDA · cross-validation · movement kinematics

Admitted 0 citing publications

References

3
  1. usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375

    We used the archived per-trial HGA features and behaviour labels (features/ and prior/, 15 patients) of this package.

  2. supportsIn 5 ds006253 patients, SEEG high-gamma 0-0.5 s after the response click did not separate error from correct decisions better than behaviour (no feedback, offline LDA; underpowered pilot) sci:sha256:95b5b226c831562f6567e099e5381740d5786287ff7a028e374975643def3942

    Consistent: HGA did not decode a decision-related label better than behaviour in ds006253.

  3. supports70–150 Hz SEEG activity after response movement did not add error-detection information to a behavior-only model in 7 patients sci:sha256:eb32aae1012b9a025a405377ca527f98dd1035b52f4cca6993cd9a1ec639cbfc

    Same pattern for a different label: move-window HGA did not add information to a behaviour model (here for change of mind, there for errors).

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.