sciscape Publications
← All publications

A fixed SEEG model of letter load showed no clear AUC gain from calibration across earlier sessions at matched trial counts in ten patients

We tested whether calibration trials from several earlier sessions improve final-session ranking of four versus eight letters. We used public SEEG data from OpenNeuro ds004752 version 1.0.1. Ten patients had at least three complete numbered sessions. The recent method used the session before the final session. The spread method used 100 draws from all earlier sessions. Each draw had the same trial count and class counts as the recent method. Each fit selected eight power features and used fixed ridge logistic regression. Trials followed a correct response and had no source artifact flag. There were 297 test trials. Mean AUC was 0.599 for recent trials and 0.587 for spread trials. The paired change was -0.012, with a patient bootstrap 95% interval from -0.062 to +0.037. The exact sign-flip p value was 0.654. Five patients gained AUC and five lost AUC. This result does not establish equal performance. Eight final sessions shared a date with the recent session. Session numbers set the test order. The test data were used in earlier work. The package contains figures, features, trial choices, fitted models, source hashes, code, and retrieval steps. Checks covered 300 public signal windows and all 2,040 fitted models.

stereoelectroencephalography · SEEG · calibration · working memory · AUC · brain-computer interface

Admitted 7 citing publications

References

3
  1. usesA fixed SEEG power model improved four versus eight letter ranking beyond history after correct responses in 13 final sessions sci:sha256:7917c63450566e88178fa4546b940d6c228e2a99f24d3a1ce66f24f825135a8f

    This work uses the exact frozen band-power features, source metadata, source hashes, and extraction code. It tests calibration across earlier sessions at matched trial and class counts in ten eligible patients.

  2. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analyzed SEEG recordings and task metadata came from OpenNeuro ds004752 version 1.0.1.

  3. supportsdoi:10.7554/eLife.78677

    This paper describes the source task and its trial sequence, including the rule that after a wrong response the next load is four letters.

Cited by

7 publications

Public catalog entries on Sciscape.