Training with gaps increased mean later state accuracy in eight SEEG recordings with 20 percent simulated sample loss
We tested whether simulated gaps in training improve a later SEEG reader. SEEG means stereoelectroencephalography. We used eight recordings from OpenNeuro ds004473 version 1.0.2. Each trial supplied a rest window and a window before a response. We fitted readers on 1,332 earlier trials and tested them on 674 later trials. Each mask removed 100 of 500 samples. We used linear interpolation. Training mixed intact input with five repaired copies. Total training weight stayed fixed. The primary test used five new gap positions. Mean balanced accuracy increased from 67.56 to 69.97 percent. The paired gain was 2.41 percentage points. Its person-bootstrap interval was 0.16 to 5.62 points. Six recordings improved. The two-sided person sign-flip p value was 0.102. This does not establish a population gain. An early-data score-offset correction gave 70.63 percent mean accuracy in a secondary test. It left AUC unchanged. Gap training slightly reduced mean AUC. The package contains all selected voltage inputs, code, predictions, figures, source records, and a retrieval recipe. No actual stimulation, online control, or transfer between sessions was tested.
stereoelectroencephalography · sample loss · gap training · signal processing · balanced accuracy · score calibration · brain-computer interfaces
References
5- usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd
This work keeps the original eight-pair selection, power features, event-selected states, and early versus later trial split. It uses these fixed choices for the new sample-loss test.
- usesA stationary Gaussian variance correction with 5 percent shrinkage reduced SEEG decoding accuracy for 20 percent simulated sample loss in eight recordings sci:sha256:495cd9ff22cc042e1f138d100dbf95110efd76545b22997f0bb2f49092bdf3ae
This work uses the exact selected SEEG voltage windows, source records, and native reader states from this package. It tests training with repaired gaps and an early score-offset correction.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
The analysis uses selected SEEG recordings from OpenNeuro ds004473 version 1.0.2.
- doi:10.1088/1741-2552%2Facae0a
- doi:10.3389/fncir.2012.00087
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesGaps of 50 samples gave higher later Brier error than gaps of 1 sample with linear repair and training on intact data in eight reused SEEG records at 20 percent loss
This earlier gap study supplied the comparison question and the reason to report probability error and score ranking. The new test uses every mask origin, equal-loss layouts, and a different matched fitting recipe.