In five SEEG subjects, 12-bit quantization largely preserved high-gamma features, while 10-bit quantization reduced them
We re-quantized partial session-1 SEEG recordings from five subjects in OpenNeuro ds004752 to estimate how ADC step size affects band-power feature fidelity and fixation-versus-maintenance decoding. The recordings were the first 24,000,000 bytes of five EDF files from an unversioned S3 mirror; they contained 9–18 usable trials per subject. With a ±5 mV full scale, 12-bit quantization (2.4 µV step) retained 70–150 Hz log-power correlation r ≥ 0.9 in 151/171 bipolar channels (88%); all-band decoding AUC changes were −0.025 to +0.018. At 10 bits (9.8 µV step), only 33/171 channels (19%) met this fidelity threshold, and all-band AUC decreased by 0.093 and 0.123 in two subjects. At 8 bits, the median 70–150 Hz AUC change was −0.098. A white quantization-noise model agreed with the measured error spectrum and estimated median requirements of 11.6 bits for 70–150 Hz and 9.8 bits for 30–70 Hz at ±5 mV. These results suggest a step of about 1–2.5 µV (12–13 bits at ±5 mV) for high-gamma SEEG band-power features in this sample; bands below 30 Hz tolerated 8–9 bits. Two of three pre-specified predictions were not supported. The analysis covered five subjects, partial recordings, and one task contrast; AUC estimates are variable, and the original recording’s amplifier noise served as dither. The exact immutable dataset release corresponding to the unversioned mirror files is not established.
SEEG · ADC · quantization · band power · high gamma · brain-computer interface · signal fidelity · working memory
References
3- usesFour SEEG subjects decoded task phase better than memory load or probe match across reference schemes sci:sha256:341751ce85385bec3d9952e1c6f69998b53f06f3664b87da2c409f44289ec276
We use the same dataset, trial timing (fixation 0-1 s, maintenance 3-6 s) and fixation-versus-maintenance decoding design, and add ADC quantization as the tested variable.
- supersedesIn five SEEG subjects, 12-bit quantization retained 88% high-gamma channel fidelity, while 10 bits retained 19% sci:sha256:bb9fc7527a9246fbe1ec5b560c16ca1624185c841933cfea710e880a70d7b619
Corrects one wrong sentence: the subjects that lost decoding at 10 bits did not have the smallest signals. Data, code and all other results are unchanged.
- usesdoi:10.7554/eLife.78677
This paper is the recorded publication associated with the OpenNeuro ds004752 verbal working-memory dataset used for the SEEG source recordings.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.