Added SEEG power gave an uncertain mean AUC gain over contact number in 17 ds004100 test patients under fixed models, independence, and null symmetry
We tested whether fixed power improved seizure onset label ranking after a model used contact number. The public source was OpenNeuro ds004100, version 1.1.3. We fitted models on 17 patients and tested them on 17 separate patients. The added feature used local Laplacian power from 80 to below 115 Hz in two short records. Mean AUC increased from 0.687 to 0.742. The mean paired gain was 0.055. Its 95 percent patient bootstrap interval was -0.039 to +0.144. The exact sign-flip test gave p = 0.268 under independent patients and symmetric differences under the zero-effect null. Inference held the fitted models fixed. The mean gain remained uncertain. Thirteen patients gained AUC, while four lost AUC. Contact number was a name-based position surrogate, not measured anatomical depth. Prior results from this cohort informed the feature and comparator. This was not external validation. All 68 pinned public signal blocks passed a fresh power check. A separate reader and spectrum calculation checked all four sample rates. The package preserves code, source metadata, compact powers, retrieval locks, features, models, predictions, inference draws, and reproduction commands.
stereoelectroencephalography · SEEG · intracranial EEG · high gamma power · seizure onset · area under the curve · patient-level inference · reproducibility
References
3- usesLower contact numbers gave mean seizure onset AUC 0.794 within mixed inferred shafts in 34 selected ds004100 SEEG patients sci:sha256:50d777142ef4ebc45c41203ba318cb2244c6b807e8d402b44d8ba5067784feec
Its contact-number result in this same cohort informed the fixed position comparator. We used its description, but no derived data or code. The new test fitted joint models on separate patients and did not select mixed-label shafts for the primary evaluation.
- usesLaplacian SEEG power from 80 to below 115 Hz separated seizure-onset labels within inferred shafts in 31 patients sci:sha256:438eadb30d57861b3a2ef58b0c3a84ddb3e3f3b457fedc8009ace9e565446832
This publication supplied the 34-patient window powers, source metadata, immutable signal range locks, and raw-check code. Its result informed the band and local reference. We verified its complete archive and rebuilt the powers from all 68 public signal blocks.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source SEEG signals and clinical channel labels, version 1.1.3; the saved metadata records CC0.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.