sciscape Publications
← All publications

An innovation filter matched dense GLS in 431 AOMIC designs with known stationary AR(2) noise, coefficients (0.6, 0.2), and marginal variance one

We tested regression after scan removal in 431 public AOMIC working memory designs. We held each design and motion mask fixed. The primary noise was stationary Gaussian AR(2), with known coefficients (0.6, 0.2) and known marginal variance one. The mask was independent of the noise. An innovation filter kept the state across removed scans. It matched independent dense GLS in every primary design. The largest relative variance difference was 2.00e-15. A rule that used only the previous retained value used exact gap correlations but overreported standard errors by 15.32% in PIOP1 and 16.02% in PIOP2. Its mean null rejection rates were 2.40% and 2.31% for a nominal 5% normal test. A planned negative second coefficient reversed the error. The package provides a NumPy AR(p) tool, a transpose operation, a proof, and a public-design audit. All eight result files matched a fresh-source repeat byte for byte. A clean NumPy build also passed independent checks. Its rounding differences are recorded. Code, fixed source hashes, reduced inputs, weights, bootstrap samples, results, checks, figures, and repeat instructions are preserved. No measured BOLD response was used. The tests do not cover estimated noise parameters or scale.

generalized least squares · autoregressive noise · innovation filter · missing scans · fMRI · covariance whitening

Admitted 3 citing publications

References

6
  1. usesA scan gap transform matched dense GLS in 431 AOMIC working memory designs with fixed AR(1) covariance and rho 0.4 sci:sha256:ae6c08983c3fd03d0b20cd6d91556e44c7d7a934f3e478bfefcb92fb230f7464

    We used the unchanged loader, working memory design builder, reduced source inputs, fixed source manifests, and retrieval recipes. Its AR(1) method motivated the AR(2) state filter. Its prior outcomes were not inputs to this calculation.

  2. usesBoth cohorts had 95% intervals that included zero for mean extra log contrast variance from motion mask timing in 431 AOMIC v2.0.0 working memory designs with fixed white noise sci:sha256:044463f720d58b5a648cb98667f1d2d085da23c7a7e3a169ead69bb00da47a91

    This publication supplied the original working memory design builder and fixed event source records inherited through the AR(1) package.

  3. usesdoi:10.18112/openneuro.ds002785.v2.0.0

    Used working memory events, motion tables, and image metadata from fixed AOMIC PIOP1 version 2.0.0.

  4. usesdoi:10.18112/openneuro.ds002790.v2.0.0

    Used working memory events, motion tables, and image metadata from fixed AOMIC PIOP2 version 2.0.0.

  5. doi:10.1038/s41597-021-00870-6
  6. doi:10.1115/1.3662552

Cited by

3 publications

Public catalog entries on Sciscape.