sciscape Publications
← All publications

A weight from other patients did not lower observed late SEEG power forecast error in 20 patients

We tested whether a weight fitted in other patients could improve a late high gamma power forecast after brain stimulation. Public OpenNeuro ds006519 data supplied 34 records from 20 patients. Each test patient was excluded from fitting. Mean absolute error was 1.133 dB with the fitted weight and 1.122 dB with a fixed half correction. Benefit over the half correction was -0.0118 dB. Its descriptive 95 percent patient bootstrap interval was -0.0776 to 0.0149 dB. All weights were fitted again within each draw. Fitting gave no observed average gain. This reused cohort does not establish equivalence or new-patient performance. All 35 raw source records passed fresh hash and spectrum checks. A separate process reproduced all 14 numerical files. The package includes code, compact spectra, source recipes, predictions, draws, checks, and three figures. The scope is offline power forecasting, not intention decoding or safe stimulation timing.

stereoelectroencephalography · high gamma power · brain stimulation · forecasting · patient bootstrap · brain-computer interfaces

Admitted 1 citing publication

References

4
  1. usesEarly fitted partial state correction lowered expected 70 to 110 Hz error after 13-sample gaps in baseline SEEG from 20 patients with independent endpoint errors of one early voltage RMS sci:sha256:77956a5dd334ccf2ef4a0877635057c633c0073106720e8db1eaea9dc73d2103

    Read after score computation to compare study scope. It tests partial filter state correction on baseline data with simulated gaps and faults. The present test uses observed post-stimulation power and fitting in other patients.

  2. usesA fixed early shift from other shafts increased late high-gamma forecast error in 99 visual SEEG records from 19 people sci:sha256:ba44636212075b16c9d78e84300068dbb3f2fb53a6c885aa753eea8eb6069513

    Used its motor four-window spectra, source metadata, raw source manifest, extraction code, and prior half-correction result. Reproduced its fixed-rule patient scores. The new test fits one weight in other patients and uses a repeated-fit patient bootstrap.

  3. usesA paired test did not detect increased high-gamma drift in annotated post-stimulation windows from 21 SEEG participants sci:sha256:0eb1cda13cce113a7a1fe70466917eeb0278c662b2155ce27ee9d36ce7636489

    The motor compact inputs and pinned raw-file manifest descend from this source study through the immediate prior forecast publication. The source publication record is preserved.

  4. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    Source dataset, version 1.0.0; the publication uses 34 eligible records from this release.

Cited by

1 publication

Public catalog entries on Sciscape.