Early cross-power correction reduced mean later bipolar SEEG curvature error against early parent spectra under source average reference: 24 participants, 20–100 Hz, excluding 55–65 Hz
We tested whether first-minute cross-power helped to predict last-minute bipolar SEEG curvature. We used public OpenNeuro ds005624 version 1.0.0 and the source common average reference. The main band was 20–100 Hz, with 55–65 Hz removed. The test used 24 participants, 34 valid records, and 2,303 disjoint pair-records. Each participant had equal group weight. Adding the early relative real cross-power term reduced mean squared curvature error by 69.4 percent against the mean early parent-contact spectrum. The 95 percent participant bootstrap interval was 51.4–81.8 percent. Error decreased in 23 of 24 participants. The own correction also reduced error by 57.0 percent against a correction from other pairs on the same shaft. The corrected estimate equals the pair's own early bipolar curvature. The result concerns temporal stability of a reference-dependent shape component. It does not identify a neural cause. The interval assumes independent, exchangeable participants. This is a new analysis of the source cohort, not an independent cohort replication. The package preserves code, input spectra, raw examples, source range hashes, results, a local plan, and reproduction instructions.
stereo-electroencephalography · cross-power · spectral curvature · common average reference · temporal prediction
References
5- usesMean bipolar SEEG slope rank agreement is higher across first and last minutes than across 20 to 45 Hz and 70 to 100 Hz in 24 participants sci:sha256:8d5133127b5edacbf513ec419691628484b8c7c286da93032fe567834b56b682
Its frequency-band and temporal rank comparison informed the choice to test the reference term before the local plan. We did not copy its arrays or results.
- usesA quadratic log-frequency model lowers SEEG shape error between the first and last minute in 24 participants at 20–100 Hz with 55–65 Hz removed sci:sha256:10c57f5b0211dec06505fe654fde6063e899c4d880876ceb72b215b7dee8baa4
This study uses all 35 pinned spectrum files, source metadata, raw examples, selection rules, and extraction code. It tests cross-power correction in the same cohort.
- usesdoi:10.18112/openneuro.ds005624.v1.0.0
The analysis uses the 1.0.0 OpenNeuro ds005624 source cohort and preserved excerpts.
- doi:10.1016/j.neuroimage.2018.08.020
- doi:10.1016/j.neuroimage.2015.02.031
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.