A 7 Hz phase input increased mean forecast error for later log response size after five calibration pulses at 86 SEEG readouts in eight patients
The added phase input increased mean later squared log RMS error by 6.68 percent in this test. The models used five early pulses at each of 86 fixed readouts in eight patients. They then forecast response size for five later pulses. The target was natural log RMS voltage from 20 to 500 ms after each pulse. A fixed 7 Hz sinusoid fitted from -500 to -20 ms supplied the added phase input. The ridge penalty was 5. Mean test error was 0.065345 for past power and 0.069712 for past power plus phase. The paired gain was -0.004368; its descriptive 95 percent person bootstrap interval was [-0.008256, -0.000802]. The exact two-sided sign-flip p value was 0.054688. The descriptive interval excludes zero for this sample and this comparison. The exact p value is above 0.05. This test does not support added forecast value for the primary phase input. The package adds verified past voltage, fitted models, event maps, predictions, and three figures. The result applies to this small linear model and this fixed clinical sample. It does not establish neural causation or live interface performance.
SEEG · phase estimation · evoked response · forecasting · ridge regression · brain-computer interface · electrical stimulation · OpenNeuro
References
5- usesA 30 Hz template derivative captured more later SEEG variation after pulses than before pulses at 86 selected sites in eight patients sci:sha256:641fb48513bf900f363416ccee06e41bcceaf624091b109af03695c0d9c384f1
Used its fixed 86 readouts, response and earlier control voltage, event maps, source records, and GPL retrieval code. Added past voltage and a five-pulse forecast test.
- usesA frozen learned forecast reduced mean simulated zero-phase pulse error at 50 ms delay in seven SEEG rest records sci:sha256:24b1a90d4cff646d87950db8a063f0c4bd0f65b7475eb4cfe09200ba447a9436
Used its simulated phase forecast study to define a separate test of response size after recorded pulses. Its voltage and models were not used.
- usesdoi:10.18112/openneuro.ds004696.v1.0.1
Source dataset ds004696 version 1.0.1 supplied the SEEG data and metadata used in this study.
- usesdoi:10.1523/JNEUROSCI.2201-22.2023
Describes the source study for the OpenNeuro SEEG dataset used here.
- supportsdoi:10.1111/epi.17528
Reports intermittent phase dependence of evoked response amplitude in clinical SEEG and motivates the question tested here.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.