sciscape Publications
← All publications

An eight-pair reader trained from SEEG ensembles reduces mean Brier error compared with half confidence in eight recordings

We tested public SEEG data from eight people in OpenNeuro ds004473 version 1.0.2. Frozen ensembles used the first 32 trials. Each ensemble had 256 logistic models and required 59–98 signal pairs. One new reader used eight fixed pairs and learned from ensemble probabilities on 52–165 middle trials per person. No middle-window class label entered its fitting loss. We tested 674 later trials. Mean Brier error decreased from 0.2299 for an eight-pair half-confidence control to 0.2147 for the new reader. The paired reduction was 0.0152 (95% person-bootstrap interval 0.0058–0.0246), with a reduction in seven people. The exact two-sided sign-flip p value was 0.0234 under independence and null sign symmetry. The large teacher had less mean error, at 0.2102. The new reader required 12–16 input contacts and one logistic evaluation per window. Broad input coverage was still required before transfer. Known events defined the windows, and source quality checks used later signal. This is an exploratory offline test on reused clinical recordings. It does not establish continuous intention detection or online BCI control. The package has code, features, frozen teachers, new fits, predictions, figures, source records, fresh raw checks, and full rerun checks.

stereoelectroencephalography · model distillation · brain-computer interface · logistic regression · Brier score

Admitted 0 citing publications

References

5
  1. usesTrial ensembles reduce SEEG probability error with eight fixed pairs after 32 calibration trials in eight recordings sci:sha256:decd64116282737a5cc36ea4a79d373ecd05b301e8fef9baa6ec353005d1c9ba

    We use its frozen early-trial ensembles and copied MIT code. We transfer their probabilities into new readers and test final input costs.

  2. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    We use its exact public SEEG power archive, trial rules, exclusions, and source retrieval code.

  3. usesTrial resampling reduced offline error at 50 percent acceptance in eight SEEG recordings with 32 calibration trials sci:sha256:761ec71bb83cda1613335fce20a94d09f5c01d0eee0ceaf99b7c786619757ab9

    We use its MIT Newton and scalar EDF check code through the preserved ensemble code. The package keeps the source attribution.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analysis uses the eight participants and version 1.0.2 feature archive from this OpenNeuro dataset.

  5. supportsdoi:10.1088/1741-2552%2Facae0a

    This source study describes the task and clinical SEEG recordings used by the dataset.

Cited by

0 publications

Public catalog entries on Sciscape.