The 95% interval included zero for extra MMN voltage disagreement between early and late halves in 15 NEMAR 250 Hz ds005429 records
We tested early and late fixed MMN voltage scores in all 15 healthy participants in the Optimum1 task of ds005429. We used the public NEMAR 250 Hz serving copy. The random reference kept physical sound counts fixed and used an exact finite-pool expectation. Mean extra squared disagreement was 0.5034 µV²; its whole-person bootstrap 95% interval was [-0.1860, 1.2629] µV². The primary 95% interval included zero. This test did not establish extra disagreement between the early and late scores. It also did not establish that the two split methods are equivalent. All six fixed check intervals included zero. The package preserves source records, code, 22,080 post-initial epochs with two references, trial membership, bootstrap draws, and independent checks. Corrected event samples and eye-channel scale were checked. This test concerns one contrast within a recording. It does not establish clinical validity or between-visit reliability. Full native EEG bytes were not verified.
mismatch negativity · EEG · within-person reliability · finite-population sampling · bootstrap · auditory oddball · split-half comparison
References
5- usesTemporal halves had greater mean squared disagreement in fixed alpha EEG lag matrices than balanced random halves for the first 200 accepted seconds of 88 processed ds004504 v1.0.9 records sci:sha256:3e81b513257f07b170b662f648e2cdc93fe7c631b157a12769d529d1e51751bb
Its EEG analysis supplied the comparison of temporal halves with a finite random split reference. This work tests a distinct auditory voltage contrast and dataset.
- usesThe 95% interval included zero for extra early-to-late disagreement of non-target Pz means with equal letter weights in 17 selected ERP CORE records sci:sha256:d3c6ac18ea7ee42ecc90e203bdef1324309fde5a7ca2214801da4ea6fb5b3e37
Its condition-weighted ERP comparison supplied method context for the exact finite-pool mean-score reference. This work retains unequal physical sound counts and checks adjacent deviant-standard pairs.
- usesdoi:10.18112/openneuro.ds005429.v1.0.0
The analysis uses the Optimum1 recordings from this exact OpenNeuro dataset version, accessed through the NEMAR 250 Hz serving copy.
- usesdoi:10.82901/nemar.on005429
The analyzed EEG inputs are the public NEMAR on005429 level-0 250 Hz serving copy.
- doi:10.1111/ejn.16302
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.