Across-channel mean removal was non-inferior for offline SEEG movement decoding in 15 patients
In archived 70–150 Hz high-gamma amplitude features from 15 patients in OpenNeuro ds006253, an offline shrinkage LDA distinguished movement from rest with mean held-out AUC 0.833 using all channels, 0.824 after subtracting the across-channel mean in each window (CMR), and 0.577 using only that mean (CM). CMR met the pre-registered non-inferiority criterion versus all channels (margin 0.02 AUC; mean difference −0.009, 95% bootstrap CI −0.020 to −0.001; exact one-sided sign-flip p = 0.027), while the confidence interval indicates a small AUC cost. All channels outperformed the mean-only decoder in 14 of 15 patients (mean difference 0.256, Holm-adjusted p = 0.0002); the mean-only decoder was above chance in 13 of 15 (Holm-adjusted p = 0.0042). In an exploratory simulation, an equal ±3 dB offset to all test channels reduced the fixed-threshold balanced accuracy for the standard features from 0.759 to 0.586–0.592; CMR remained at 0.759. The result agrees with prior work in a second SEEG dataset and task. The analysis is offline, uses one session per patient and task windows aligned to known events, compares different task phases, simulates equal shifts across channels, and uses only the available 70–150 Hz features; it does not establish performance for causal online detection or channel-specific drift.
SEEG · movement decoding · high-gamma amplitude · common-mode removal · brain-computer interface · shrinkage LDA · gain robustness
References
4- supportsCommon-mode removal was non-inferior for offline SEEG key-press AUC and invariant to simulated uniform gain in eight patients sci:sha256:d699a65f56285803b96cde40213957fdc760e5847eb566f062106630db7cbe5a
Same non-inferiority margin and gain simulation; same result in ds006253.
- SEEG key-press decoding in eight subjects used channel patterns; removing the channel mean preserved AUC within 0.02 sci:sha256:44521d3ae8746b7e500ff46f2c32d5e111912fd41c2df2fad9ba52213d6b2647
[Legacy relation: reproduces] Same common-mode test, done in a second SEEG dataset and task.
- usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375
Archived ds006253 HGA features and decoder code.
- usesdoi:10.18112/openneuro.ds006253.v1.0.3
The analyzed archived author derivatives and behavioral files are from OpenNeuro ds006253; the recorded release is v1.0.3.
Cited by