30–80 Hz bipolar SEEG maps retained positive mean correlation across file excerpts in 36 epilepsy patients after linear 1–30 Hz map and geometry controls
We tested whether 30 to 80 Hz bipolar SEEG map detail repeats after lower-band and geometry controls. We used two public file excerpts per patient from OpenNeuro ds004100 version 1.1.3. Each map averages the magnitudes of correlations from two 25 second blocks. Both 1 to 30 Hz maps, named shaft pairs, individual signals, and log distance form the common linear control space. The mean residual correlation was 0.576. The 95 percent patient bootstrap interval was 0.528 to 0.623. All 36 patient scores were positive. All seven fixed secondary checks had positive means. Fresh retrieval reproduced all 72 covariance inputs and all 41 analysis outputs with exactly equal bytes. An independent matrix calculation and a dense solver checked all primary results. The package preserves code, inputs, raw source pins, maps, bootstrap draws, and repeat instructions. The evidence applies to short clinical excerpts. File timing is unknown. Stable recording effects can contribute to repeatability. This exploratory analysis uses a previously studied cohort and does not identify neural causes.
stereoelectroencephalography · SEEG · correlation maps · signal processing · frequency bands · epilepsy
References
5- usesBipolar 1–80 Hz SEEG correlation magnitude maps had positive correlations between file excerpts after signal, shaft pair, and log distance controls in 36 epilepsy patients sci:sha256:36170aff18fbecc7f57d9bf3c205be69a8ce1d45617c7e9600a74df38e629542
Introduced the inherited covariance inputs with separate raw filter ranges. We use its filter design and raw source recipe for fresh reconstruction.
- usesBlock variance shrinkage reduced mean squared error for 1–80 Hz bipolar SEEG correlations between shafts in separate files from 36 patients sci:sha256:fd6b98927a0cd6fab67e659b3dab9f8d5cba3aea96f3d1603f48ed3aa09e97a9
Supplied the 72 contact covariance archives, public metadata, and source manifests used as the analysis inputs. All input and metadata hashes were checked.
- usesIn 36 patients, fixed 1–80 Hz SEEG contrasts showed larger covariance shape changes between files than within files sci:sha256:f663d71b5fe518a4b49eafc4b56264ce4f5dc80dad0e319618842dac64c731a5
Supplied the preserved EDF range parser and the inherited contact selection rules. Its MIT notices are preserved.
- usesSEEG modes learned in the target band captured more scaled covariance between shafts in separate files from 36 epilepsy patients at 1–30 and 30–80 Hz sci:sha256:c7d0d78b39c231d770b52d4a9725d271150234e9665d80a63666a928ca72967c
Its frequency band mode result motivated the edge map question. This study tests a different endpoint on the same cohort.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The analyzed inputs derive from the HUP iEEG Epilepsy Dataset, OpenNeuro ds004100 version 1.1.3; the publication records the source version and CC0 license.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesBlock products changed a mean 37 percent of top 20 percent SEEG links at 30 to 80 Hz in 36 patients
We used all 72 contact covariance inputs, the inherited 36 patient layouts, metadata, and raw retrieval records. These inputs enabled the new link selection comparison. We independently retrieved all raw ranges and reproduced the input file hashes.