Spread sampling gave an uncertain gain in HFO list agreement at 60 seconds of exposure in seven sleep SEEG patients
We tested whether five separated samples improve high frequency oscillation (HFO) list agreement with other sleep SEEG records. Both designs used 60 seconds of exposure. The source was OpenNeuro ds003498 version 1.1.1. The study used 135 records from seven patients with depth electrodes. All integer-second origins received equal weight under circular sampling. Spread agreement was 65.56%. Continuous agreement was 65.05%. The equal-patient gain was 0.52 percentage points. Its 95% patient bootstrap interval was -0.02 to +1.01. The exact sign-flip p value was 0.125. Thus, the data did not show a clear gain. Spread samples were empty less often. Selecting one top pair changed the mean contrast direction. We also prove equal expected agreement under independent, uniform event starts and a fixed separate target. The study measures detector-mark reproducibility. It does not test surgical accuracy. The package preserves source annotations, code, counts, scores, random draws, checksums, and reproduction instructions. All 12 numerical files were reproduced exactly. This is an exploratory study in a reused cohort.
high frequency oscillations · HFO · stereoelectroencephalography · SEEG · epilepsy · sampling design · reproducibility · event detection
References
7- usessci:sha256:74e22fdac1f333c2b0ddb2a290f381a26fb548555b4502c3a28eb34f5d53248c not known to Sciscape
This work supplied earlier source retrieval and evidence of uneven HFO counts. It motivated the spread sampling question.
- usessci:sha256:a22be20f9664505ea33080cefb407ff7b6665b5b75e6cc0193ba4ef160713581 not known to Sciscape
This work supplied the checked source archive, scan files, source loader, and retrieval scripts.
- usesMean top overlapping HFO pair agreement was 3.3 percentage points below a conditional independent event model in 131 sleep SEEG records from eight patients sci:sha256:3476f900b125550daf85a57bf366f145d09adf243d15bf4c4b8a918d717c00de
This work reported one-top-pair repeatability in the same source. It informed the planned one-top-pair check.
- usesdoi:10.18112/openneuro.ds003498.v1.1.1
The analysis used OpenNeuro ds003498 version 1.1.1, pinned in the source records to the analyzed commit.
- usesdoi:10.6080/K06Q1VD5
The publication identifies this as the original CRCNS source for the OpenNeuro dataset.
- supportsdoi:10.1038/s41598-017-13064-1
The source study is cited for the source sleep-interval selection and the identification of the cohort as temporal lobe epilepsy patients with depth electrodes.
- doi:10.1212/WNL.0000000000218225
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.