Mean bits per source word were higher inside detected voltage runs for fixed lossless 100 ms packets in 21 ds006519 SEEG records

We measured exact SEEG packet size before, inside, and after detected periodic voltage runs. We used OpenNeuro ds006519 version 1.0.0. The main set had 21 records from 14 people with agreement in the final detector landmark. Each independent 100 ms packet used a fixed four-mode lossless code and a 32-byte header. The equal-person mean rose from 18.053 to 18.868 bits per source word inside the runs. The paired increase was 0.815 bits, with a 95% person bootstrap interval of 0.447 to 1.211. The ratio of cohort means increased by 4.51%. An equal-person mean of 64.6% of run packets exceeded each record's before-period 95th percentile size. The increase remained after exclusion of channels on the stimulation shaft. All 45,683 scored packets decoded to exact source bits. The package has code, source hashes, metadata, packet examples, tables, and three figures. The result applies to the selected voltage runs and stored float32 words. Hardware pulse times, neural effects, and device power remain untested.

lossless compression · stereo-EEG · intracranial EEG · brain interfaces · packet size · electrical stimulation · data links

Admitted 0 citing publications

References

5
  1. usesA fixed detector found periodic voltage runs in 31 of 35 SEEG records from ds006519 version 1.0.0 sci:sha256:ea4058aa1dce526e987cca14e771bbeab34ccf9025624ac6983dbb7c42876d8e

    Uses the fixed timing table, agreement labels, full source manifest, and unchanged detector. Replays all five difference-score variants on fresh full source files.

  2. usesAdded word transforms reduced lossless 100 ms packet size in seven SEEG rest records and gave no gain in 35 stimulation records sci:sha256:b0f851eebc462e59baf931936c46b65d434fb531491e3a5eb8e30ede3d9c8197

    Uses the unchanged four-mode baseline code, packet format, and source channel map. Extends the size test into detected periodic voltage runs.

  3. usesChannel order reduced the mean size of independent 100 ms zlib packets for stored float32 SEEG in 35 stimulation records sci:sha256:7c817bc0e3572ccd79ecd53218c52f4f0791b9411ce9ace0ba27f3443aa39526

    Uses the reported channel-order result to limit claims about the fixed baseline. That study tested before and after periods, not active voltage runs.

  4. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    The analysis uses source files from OpenNeuro ds006519 version 1.0.0.

  5. doi:10.1016/j.neuroimage.2026.121822

Cited by

0 publications