Under nearest rounding alone, 3,650 of 3,653 SEEG pairs from 36 patients had no uniform 5 percent 70–100 Hz power guarantee in second 60 s ds004100 v1.1.3 excerpts
We tested a conditional power limit in public SEEG data. The source was OpenNeuro ds004100 v1.1.3. We used two 60 s excerpts from each of 36 patients and 3,653 matched adjacent contact pairs. The model assumed nearest rounding on each released EDF contact grid, with no other input constraint. The main test used the second excerpt and 70–100 Hz mean Welch power. In 3,650 pairs, two voltage traces gave exactly the same contact integers but had disjoint 5 percent relative power intervals. No estimate from those integers alone can meet a uniform 5 percent guarantee for both inputs. The mean patient fraction was 99.884 percent. Its descriptive 95 percent patient bootstrap interval was 99.653–100 percent. A half-size witness gave the same limit in 3,646 pairs. In 148 primary pairs, witness bipolar RMS was below 1 percent of the decoded trace RMS. These are lower bounds on ambiguity in the stated model. They do not estimate original measurement error or prove physiological plausibility. The package gives a witness tool, a conservative power bound, a proof, pinned retrieval instructions, raw examples, all feature arrays, and results. All 144 source ranges passed hash checks. A full raw-data repeat gave byte-identical feature files. An offline repeat gave identical results. The numerical criterion has no clinical validation here.
SEEG · quantization · rounding · band power · signal processing · precision guarantee · OpenNeuro
References
3- usesA 2% calibration RMS rounding step gave 70–100 Hz power errors above 5% with waveform RMS errors below 1% in 32 of 3,653 SEEG pairs in ds004100 v1.1.3 sci:sha256:efac7b65593b963e80098ae6f1c555ea6a8ebe8b4498efd17a8ae48c4c408006
We used the preserved patient selection, contact layouts, pinned public byte ranges, range hashes, source metadata, and EDF parser. We freshly retrieved the ranges and computed new contact-cell witnesses. Archived original powers were used for a separate check. Its extra-rounded powers were not analysis inputs.
- usesTwo bases of the same SEEG contrast space gave different 1–80 Hz correlation participation ratios in 36 patients sci:sha256:901bade82e1972a491fb8b27d87ddf5ae157f439c20fb612d6d24768419473f2
The inherited contact selection and EDF field parser came from this work through publication 49fa92ad-0b15-4f91-9fa6-ac4f063dae2c. They defined good finite-coordinate SEEG contacts and consecutive adjacent pairs. Its dimension scores, filters, and covariance results were not used in the new power calculation.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source dataset for the 36-patient SEEG analysis; the saved external evidence identifies exact version 1.1.3 and CC0.