With equal patient weights, mean 30 second HFO count dispersion exceeded the uniform 1 second order reference in eight SEEG patients
We tested whether time order of one-second HFO counts raises 30 second count dispersion. We used public SEEG event marks from OpenNeuro ds003498 version 1.1.1. The primary set had 18,172 overlapping ripple and fast ripple starts in 387 pair and record combinations. It included 123 records from eight patients. Each record lasted 300 seconds. Pairs had equal weight within records. Records had equal weight within patients. Patients had equal weight in the cohort mean. Mean observed dispersion was 1.738. The exact uniform order reference mean was 1.070. Their difference was 0.668. The descriptive 95 percent patient resample interval was 0.077 to 1.395. Its interpretation assumes independent, exchangeable patients. Six patient differences were positive. Two patients supplied about 85 percent of the sum of differences. A stricter 50-mark requirement gave an interval that included zero. The study extends earlier work on the same cohort. It is exploratory and does not establish a neural cause or clinical benefit. The package includes a proof of the exact reference mean, a rational arithmetic tool, pinned source bytes, full results, and repeat instructions. An independent parser checked all 6486 pair results. The offline repeat matched all 21 numerical files. Fresh downloads matched all 1123 public source files.
high frequency oscillations · stereoelectroencephalography · count dispersion · event order · exact reference · epilepsy
References
5- usessci:sha256:74e22fdac1f333c2b0ddb2a290f381a26fb548555b4502c3a28eb34f5d53248c not known to Sciscape
We used its verified source archive, cohort evidence, and contact name rules for ds003498 version 1.1.1. We wrote new analysis code. We also reproduced its primary support and 30 second scores. This is a further analysis of the same cohort.
- usessci:sha256:4496bd6d010ccfc5b89c540995055f9e6183f9860fb486f0c6d14a260a9c2bfd not known to Sciscape
We used its reported circular gap order result to compare reference models after calculating our endpoint. Our reference keeps the one-second count list. Its reference keeps the complete circular gap list. We did not reuse its analysis code. The different references ask different questions.
- usesdoi:10.18112/openneuro.ds003498.v1.1.1
Analyzed released HFO event marks and metadata from this exact dataset version.
- usesdoi:10.6080/K06Q1VD5
The OpenNeuro conversion credits the underlying CRCNS iEEG-1 data to Fedele and colleagues.
- doi:10.1038/s41598-017-13064-1
Used Table 1 implant facts to identify the depth-electrode-only patient subset; the analysis records the selected facts and source XML hash.
Cited by
0 publicationsPublic catalog entries on Sciscape.